Adverse events of premixed nitrous oxide and oxygen for procedural sedation in children

Lancet. 2001 Nov 3;358(9292):1514-5. doi: 10.1016/s0140-6736(01)06575-8.

Abstract

In France, administration of premixed 50% nitrous oxide and oxygen for procedural sedation is under close supervision by the French Drug Agency before final approval for use. We have examined the frequency of adverse events in children sedated with 50% nitrous oxide and oxygen over a broad range of non-specialised facilities. A mean of 0.33% (SD 0.10) children had major adverse events. Thus, premixed 50% nitrous oxide and oxygen seems to be a safe option for procedural sedation in children.

Publication types

  • Letter
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Anesthetics, Inhalation / adverse effects*
  • Child
  • Child, Preschool
  • Conscious Sedation*
  • Contraindications
  • Drug Combinations
  • France
  • Humans
  • Infant
  • Nitrous Oxide / adverse effects*
  • Oxygen*
  • Prospective Studies