Peripheral arterial disease: comparison of color duplex US and contrast-enhanced MR angiography for diagnosis

Radiology. 2005 May;235(2):699-708. doi: 10.1148/radiol.2352040089.

Abstract

Purpose: To prospectively compare the diagnostic accuracies of color duplex ultrasonography (US) and contrast material-enhanced magnetic resonance (MR) angiography and to assess interobserver agreement regarding contrast-enhanced MR angiographic findings in patients suspected of having peripheral arterial disease (PAD).

Materials and methods: The institutional review board approved the study, and all patients provided signed informed consent. Two hundred ninety-five patients referred for diagnostic and preinterventional work-up of PAD with duplex US also underwent gadolinium-enhanced MR angiography. Data sets were reviewed for presence or absence of 50% or greater luminal reduction, which indicated hemodynamically significant stenosis, and to determine interobserver agreement. At duplex US, a peak systolic velocity ratio of 2.5 or greater indicated significant stenosis. Primary outcome measures were differences between duplex US and contrast-enhanced MR angiography in sensitivity and specificity for detection of significant stenosis, as assessed with the McNemar test, and interobserver agreement between the two contrast-enhanced MR angiogram readings, expressed as quadratic weighted kappa values. Intraarterial digital subtraction angiography (DSA) was the reference standard.

Results: Two hundred forty-nine patients had at least one hemodynamically significant stenotic lesion at contrast-enhanced MR angiography, duplex US, or both examinations. One hundred fifty-two patients underwent intraarterial DSA. The quadratic weighted kappa for agreement regarding the presence of 50% or greater stenosis at contrast-enhanced MR angiography was 0.89 (95% confidence interval [CI]: 0.87, 0.91). Sensitivity of duplex US was 76% (95% CI: 69%, 82%); specificity, 93% (95% CI: 91%, 95%); and accuracy, 89%. Sensitivity and specificity of contrast-enhanced MR angiography were 84% (95% CI: 78%, 89%) and 97% (95% CI: 95%, 98%), respectively; accuracy was 94%. Sensitivity (P = .002) and specificity (P = .03) of contrast-enhanced MR angiography were significantly higher.

Conclusion: Results of this prospective comparison between contrast-enhanced MR angiography and duplex US provide evidence that contrast-enhanced MR angiography is more sensitive and specific for diagnosis and preinterventional work-up of PAD.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Angiography, Digital Subtraction
  • Arterial Occlusive Diseases / diagnosis*
  • Contrast Media / administration & dosage
  • Humans
  • Image Processing, Computer-Assisted*
  • Intermittent Claudication / diagnosis*
  • Magnetic Resonance Angiography*
  • Middle Aged
  • Prospective Studies
  • Reference Values
  • Sensitivity and Specificity
  • Ultrasonography, Doppler, Color*

Substances