A sensitive measure of surface stress in the resting neutrophil

Biophys J. 1992 Jun;61(6):1664-70. doi: 10.1016/S0006-3495(92)81970-7.

Abstract

The simplest parameterized model of the "passive" or "resting receptive" neutrophil views the cell as being composed of an outer cortex surrounding an essentially liquid-like highly viscous cytoplasm. This cortex has been measured to maintain a small persistent tension of approximately 0.035 dyn/cm (Evans and Yeung. 1989. Biophys. J. 56:151-160) and is responsible for recovering the spherical shape of the cell after large deformation. The origin of the cortical tension is at present unknown, but speculations are that it may be an active process related to the sensitivity of a given cell to external stimulation and the "passive-active" transition. In order to characterize further this feature of the neutrophil we have used a new micropipet manipulation method to give a sensitive measure of the surface stress as a function of the surface area dilation of the highly ruffled cellular membrane. In the experiment, a single cell is driven down a tapered pipet in a series equilibrium deformation positions. Each equilibrium position represents a balance between the stress in the membrane and the pressure drop across the cell. For most cells that seemed to be "passive," as judged by their spherical appearance and lack of pseudopod activity, area dilations of approximately 30% were accompanied by only a small increase in the membrane tension, indicative of a very small apparent elastic area expansion modulus (approximately 0.04 dyn/cm). Extrapolations back to zero area dilation gave a value for the tension in the resting membrane of 0.024 +/- 0.003 dyn/cm, in close agreement with earlier measures. A few cells showed virtually no change in cortical tension and fit the persistent cortical tension model of Evans and Yeung (1989. Biophys. J. 56:151-160). However, other cells that also appeared "passive," as judged by their spherical appearance, had membrane tensions that increased as the apparent surface area was increased. Thus, the postulated,persistent "cortical tension" does not appear to be a unique and constant parameter for all cells as the membrane area is dilated.This measurement of membrane tension could represent a sensitive indication of the first stages of cell activation and the"passive-active" transition.

Publication types

  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Cell Membrane / physiology*
  • Cell Membrane / ultrastructure
  • Erythrocytes / physiology
  • Erythrocytes / ultrastructure
  • Humans
  • Mathematics
  • Microscopy, Electron, Scanning
  • Models, Biological
  • Neutrophils / physiology*
  • Neutrophils / ultrastructure
  • Stress, Mechanical