Abstract

Introduction: Conventional imaging (CI) is known to have limitations with respect to staging of patients with primary or relapsed prostate cancer. Positron emission tomography/computed tomography (PET/CT) with (18)F-flurodeoxyglucose (FDG) is also often suboptimal because of low tracer avidity, but (18)F-fluorocholine (FCH) appears to be a promising alternative molecular imaging probe. We report a prospective pilot study of PET/CT comparing both tracers for staging and restaging of patients with prostate cancer.

Methods: Sixteen prostate cancer patients were evaluated (7 for staging and 9 for restaging). All patients also underwent CI, comprising at least an abdominopelvic CT and a bone scan. All imaging results and other relevant data were extracted from the imaging reports and medical charts.

Results: Based on all imaging-detected disease sites, both FCH-PET/CT and FDG-PET/CT (79%) were more sensitive than CI (14%), with the highest number of sites of nodal and distant disease on FCH PET/CT. FCH-PET/CT alone would have provided sufficient clinical information to form an appropriate management plan in 88% of cases, as compared with 56% for CI.

Conclusion: FCH-PET/CT has the potential to impact on the management of patients with prostate cancer significantly more often than CI.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Choline / analogs & derivatives*
  • Fluorodeoxyglucose F18*
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Neoplasm Staging
  • Pilot Projects
  • Positron-Emission Tomography / methods*
  • Prospective Studies
  • Prostate / diagnostic imaging
  • Prostate / pathology
  • Prostatic Neoplasms / diagnosis*
  • Prostatic Neoplasms / pathology*
  • Radiographic Image Enhancement / methods
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18
  • fluorocholine
  • Choline