Brightness mode quality ultrasound imaging examination technique (B-QUIET): quantifying quality in ultrasound imaging

J Ultrasound Med. 2011 Dec;30(12):1649-55. doi: 10.7863/jum.2011.30.12.1649.

Abstract

Objectives: Ultrasound image interpretation and education relies on obtaining a high-quality ultrasound image; however, no literature exists to date attempting to define a high-quality ultrasound image. The purpose of this study was to design and perform a pilot reliability study of the Brightness Mode Quality Ultrasound Imaging Examination Technique (B-QUIET) method for ultrasound quality image assessment.

Methods: A single sonologist performed a Trinity hypotensive ultrasound protocol on 3 participants of varying body types. Each participant's ultrasound examination was repeated in 4 locations; static clinic location, mobile ambulance, airplane, and helicopter. Images were reviewed by a sonographer, radiologist, and emergency medicine physician using the B-QUIET method and underwent statistical analysis using generalizability theory for reliability of the assessments using the tool.

Results: The B-QUIET method showed high reliability of most subscale items. Approximately two-thirds of the reviewed images had complete inter-rater reliability on 90% of the items. There was relatively low inter-rater reliability for the Identification/ Orientation subscale items. The inter-rater reliability κ value was calculated as 0.676 overall for the method.

Conclusions: The need for a standardized method to evaluate the quality of an ultrasound image is well documented. The B-QUIET method represents the first attempt to quantify the sonographer component of ultrasound images. Further reliability and validation studies of this method will be needed; however, it represents a tool for standardized ultrasound interpretation, ultrasound training, and institutional quality assessment.

MeSH terms

  • Algorithms*
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Observer Variation
  • Ohio
  • Professional Competence*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Ultrasonography / methods*