Scan-rescan reproducibility of quantitative assessment of inflammatory carotid atherosclerotic plaque using dynamic contrast-enhanced 3T CMR in a multi-center study

J Cardiovasc Magn Reson. 2014 Aug 1;16(1):51. doi: 10.1186/s12968-014-0051-7.

Abstract

Background: The aim of this study is to investigate the inter-scan reproducibility of kinetic parameters in atherosclerotic plaque using dynamic contrast-enhanced (DCE) cardiovascular magnetic resonance (CMR) in a multi-center setting at 3T.

Methods: Carotid arteries of 51 subjects from 15 sites were scanned twice within two weeks on 3T scanners using a previously described DCE-CMR protocol. Imaging data with protocol compliance and sufficient image quality were analyzed to generate kinetic parameters of vessel wall, expressed as transfer constant (K trans ) and plasma volume (v p ). The inter-scan reproducibility was evaluated using intra-class correlation coefficient (ICC) and coefficient of variation (CV). Power analysis was carried out to provide sample size estimations for future prospective study.

Results: Ten (19.6%) subjects were found to suffer from protocol violation, and another 6 (11.8%) had poor image quality (n=6) in at least one scan. In the 35 (68.6%) subjects with complete data, the ICCs of K trans and v p were 0.65 and 0.28, respectively. The CVs were 25% and 62%, respectively. The ICC and CV for v p improved to 0.73 and 28% in larger lesions with analyzed area larger than 25 mm2. Power analysis based on the measured CV showed that 50 subjects per arm are sufficient to detect a 20% difference in change of K trans over time between treatment arms with 80% power without consideration of the dropout rate.

Conclusion: The result of this study indicates that quantitative measurement from DCE-CMR is feasible to detect changes with a relatively modest sample size in a prospective multi-center study despite the limitations. The relative high dropout rate suggested the critical needs for intensive operator training, optimized imaging protocol, and strict quality control in future studies.

Publication types

  • Multicenter Study
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Carotid Arteries / pathology*
  • Carotid Artery Diseases / diagnosis*
  • Carotid Artery Diseases / pathology
  • China
  • Contrast Media*
  • Feasibility Studies
  • Female
  • Gadolinium DTPA*
  • Humans
  • Image Interpretation, Computer-Assisted
  • Inflammation / diagnosis*
  • Inflammation / pathology
  • Magnetic Resonance Angiography / methods*
  • Male
  • Middle Aged
  • North America
  • Patient Dropouts
  • Plaque, Atherosclerotic*
  • Predictive Value of Tests
  • Prospective Studies
  • Reproducibility of Results
  • Time Factors

Substances

  • Contrast Media
  • Gadolinium DTPA