Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up

Surg Endosc. 2018 Apr;32(4):1929-1936. doi: 10.1007/s00464-017-5886-1. Epub 2017 Oct 23.

Abstract

Background: Long-term resorbable mesh represents a promising technology for complex ventral and incisional hernia repair (VIHR). Preclinical studies indicate that poly-4-hydroxybutyrate (P4HB) resorbable mesh supports strength restoration of the abdominal wall. This study evaluated outcomes of high-risk subjects undergoing VIHR with P4HB mesh.

Methods: This was a prospective, multi-institutional study of subjects undergoing retrorectus or onlay VIHR. Inclusion criteria were CDC Class I, defect 10-350 cm2, ≤ 3 prior repairs, and ≥ 1 high-risk criteria (obesity (BMI: 30-40 kg/m2), active smoker, COPD, diabetes, immunosuppression, coronary artery disease, chronic corticosteroid use, hypoalbuminemia, advanced age, and renal insufficiency). Physical exam and/or quality of life surveys were performed at regular intervals through 18 months (to date) with longer-term, 36-month follow-up ongoing.

Results: One hundred and twenty-one subjects (46M, 75F) with an age of 54.7 ± 12.0 years and BMI of 32.2 ± 4.5 kg/m2 (mean ± SD), underwent VIHR. Comorbidities included the following: obesity (n = 95, 78.5%), hypertension (n = 72, 59.5%), cardiovascular disease (n = 42, 34.7%), diabetes (n = 40, 33.1%), COPD (n = 34, 28.1%), malignancy (n = 30, 24.8%), active smoker (n = 28, 23.1%), immunosuppression (n = 10, 8.3%), chronic corticosteroid use (n = 6, 5.0%), advanced age (n = 6, 5.0%), hypoalbuminemia (n = 3, 2.5%), and renal insufficiency (n = 1, 0.8%). Hernia types included the following: primary ventral (n = 17, 14%), primary incisional (n = 54, 45%), recurrent ventral (n = 15, 12%), and recurrent incisional hernia (n = 35, 29%). Defect and mesh size were 115.7 ± 80.6 and 580.9 ± 216.1 cm2 (mean ± SD), respectively. Repair types included the following: retrorectus (n = 43, 36%), retrorectus with additional myofascial release (n = 45, 37%), onlay (n = 24, 20%), and onlay with additional myofascial release (n = 8, 7%). 95 (79%) subjects completed 18-month follow-up to date. Postoperative wound infection, seroma requiring intervention, and hernia recurrence occurred in 11 (9%), 7 (6%), and 11 (9%) subjects, respectively.

Conclusions: High-risk VIHR with P4HB mesh demonstrated positive outcomes and low incidence of hernia recurrence at 18 months. Longer-term 36-month follow-up is ongoing.

Keywords: Hernia repair; Infection; Mesh; Poly-4-hydroxybutyrate; Recurrence; Seroma.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Female
  • Follow-Up Studies
  • Hernia, Ventral / classification
  • Hernia, Ventral / surgery*
  • Herniorrhaphy / methods*
  • Humans
  • Hydroxybutyrates*
  • Incidence
  • Incisional Hernia / classification
  • Incisional Hernia / surgery*
  • Male
  • Middle Aged
  • Postoperative Complications / epidemiology*
  • Prospective Studies
  • Quality of Life
  • Recurrence
  • Surgical Mesh*
  • Time Factors
  • Treatment Outcome
  • United States / epidemiology

Substances

  • Hydroxybutyrates