Patients undergoing recurrent CT scans: assessing the magnitude

Eur Radiol. 2020 Apr;30(4):1828-1836. doi: 10.1007/s00330-019-06523-y. Epub 2019 Dec 2.

Abstract

Objectives: To assess percent of patients undergoing multiple CT exams that leads to cumulative effective dose (CED) of ≥ 100 mSv and determine their age distribution.

Methods: Data was retrieved retrospectively from established radiation dose monitoring systems by setting the threshold value of 100 mSv at four institutions covering 324 hospitals. The number of patients with CED ≥ 100 mSv only from recurrent CT exams during a feasible time period between 1 and 5 years was identified. Age and gender distribution of these patients were assessed to identify the magnitude of patients in the relatively lower age group of ≤ 50 years.

Results: Of the 2.5 million (2,504,585) patients who underwent 4.8 million (4,819,661) CT exams during the period of between 1 and 5 years, a total of 33,407 (1.33%) patients received a CED of ≥ 100 mSv with an overall median CED of 130.3 mSv and maximum of 1185 mSv. Although the vast majority (72-86%) of patients are > 50 years of age, nearly 20% (13.4 to 28%) are ≤ 50 years. The minimum time to accrue 100 mSv was a single day at all four institutions, an unreported finding to date.

Conclusions: We are in an unprecedented era, where patients undergoing multiple CT exams and receiving CED ≥ 100 mSv are not uncommon. While underscoring the need for imaging appropriateness, the consideration of the number and percent of patients with high exposures and related clinical necessities creates an urgent need for the industry to develop CT scanners and protocols with sub-mSv radiation dose, a goal that has been lingering.

Key points: • We are in an era where patients undergoing multiple CT exams during a short span of 1 to 5 years are not uncommon and a sizable fraction among them are below 50 years of age. • This leads to cumulative radiation dose to individual patients at which radiation effects are of real concern. • There is an urgent need for the industry to develop CT scanners with sub-mSv radiation dose, a goal that has been lingering.

Keywords: Patient safety; Radiation dosage; Radiation protection; Radiologic technology; Risk.

MeSH terms

  • Adult
  • Age Distribution
  • Female
  • Humans
  • Male
  • Middle Aged
  • Radiation Dosage*
  • Retrospective Studies
  • Sex Distribution
  • Tomography Scanners, X-Ray Computed
  • Tomography, X-Ray Computed / methods
  • Tomography, X-Ray Computed / statistics & numerical data*
  • Young Adult