Stent interventions for pulmonary artery stenosis improve bi-ventricular flow efficiency in a swine model

J Cardiovasc Magn Reson. 2021 Feb 25;23(1):13. doi: 10.1186/s12968-021-00709-4.

Abstract

Background: Branch pulmonary artery (PA) stenosis (PAS) commonly occurs in patients with congenital heart disease (CHD). Prior studies have documented technical success and clinical outcomes of PA stent interventions for PAS but the impact of PA stent interventions on ventricular function is unknown. The objective of this study was to utilize 4D flow cardiovascular magnetic resonance (CMR) to better understand the impact of PAS and PA stenting on ventricular contraction and ventricular flow in a swine model of unilateral branch PA stenosis.

Methods: 18 swine (4 sham, 4 untreated left PAS, 10 PAS stent intervention) underwent right heart catheterization and CMR at 20 weeks age (55 kg). CMR included ventricular strain analysis and 4D flow CMR.

Results: 4D flow CMR measured inefficient right ventricular (RV) and left ventricular (LV) flow patterns in the PAS group (RV non-dimensional (n.d.) vorticity: sham 82 ± 47, PAS 120 ± 47; LV n.d. vorticity: sham 57 ± 5, PAS 78 ± 15 p < 0.01) despite the PAS group having normal heart rate, ejection fraction and end-diastolic volume. The intervention group demonstrated increased ejection fraction that resulted in more efficient ventricular flow compared to untreated PAS (RV n.d. vorticity: 59 ± 12 p < 0.01; LV n.d. vorticity: 41 ± 7 p < 0.001).

Conclusion: These results describe previously unknown consequences of PAS on ventricular function in an animal model of unilateral PA stenosis and show that PA stent interventions improve ventricular flow efficiency. This study also highlights the sensitivity of 4D flow CMR biomarkers to detect earlier ventricular dysfunction assisting in identification of patients who may benefit from PAS interventions.

Keywords: 4D flow MRI; Congenital heart disease; Pediatrics; Right ventricle.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Computed Tomography Angiography
  • Disease Models, Animal
  • Endovascular Procedures / instrumentation*
  • Magnetic Resonance Imaging, Cine
  • Myocardial Contraction
  • Myocardial Perfusion Imaging
  • Pulmonary Artery / diagnostic imaging
  • Pulmonary Artery / physiopathology*
  • Recovery of Function
  • Stenosis, Pulmonary Artery / diagnostic imaging
  • Stenosis, Pulmonary Artery / physiopathology
  • Stenosis, Pulmonary Artery / therapy*
  • Stents*
  • Sus scrofa
  • Ventricular Dysfunction, Right / diagnostic imaging
  • Ventricular Dysfunction, Right / physiopathology
  • Ventricular Dysfunction, Right / therapy*
  • Ventricular Function, Left*
  • Ventricular Function, Right*