Rapid determination of glyphosate and glufosinate in human blood by probe electrospray ionization tandem mass spectrometry

J Chromatogr A. 2024 May 10:1722:464846. doi: 10.1016/j.chroma.2024.464846. Epub 2024 Mar 27.

Abstract

In forensic science, glyphosate (GLYP) and glufosinate (GLUF), a class of non-selective broad-spectrum herbicides, have been frequently encountered in many fatal poisoning and suicide cases due to their widespread availability. Therefore, it is essential to develop an effective method for detecting these compounds. Some conventional methods, such as gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS), have been reported to detect these compounds. However, these methods are not ideal for their time-consuming and non-sensitive feature. Herein, probe electrospray ionization (PESI) tandem mass spectrometry (MS/MS), a fast and sensitive technique, was applied for the determination of GLYP and GLUF in human blood, which can obtain analytical results within 0.5 min without derivatization and chromatographic separation. After protein precipitation of blood samples, the supernatant was mixed with isopropanol and ultra-pure water (1:1 v/v). Then, 8 μL of the mixture was introduced into the plastic sample plate for PESI-MS/MS analysis. The limits of detection (LODs) of the method were 0.50 μg/mL and 0.25 μg/mL for two analytes, and the limits of quantitation (LOQs) were both 1.00 μg/mL, which are higher than the concentration of reported poisoning and fatal cases. In the linear range of 1-500 μg/mL, the regression coefficients (r2) for GLYP and GLUF were over 0.99. The matrix effects ranged from 94.8 % to 119.5 %, and the biases were below 4.3 %. The recoveries ranged between 84.8 % and 107.4 %, and the biases were below 7.6 %. Meanwhile, the method was effectively utilized to detect and quantify the blood, urine, and other samples. Consequently, the results suggest that PESI-MS/MS is a straightforward, fast, and sensitive method for detecting GLUF and GLYP in forensics. In the future, PESI-MS/MS will become an indispensable technique for polar substances in grassroots units of public security where rapid detection is essential.

Keywords: Blood; Glufosinate; Glyphosate; Probe electrospray ionization; Tandem mass spectrometry.

MeSH terms

  • Aminobutyrates* / blood
  • Glycine* / analogs & derivatives
  • Glycine* / blood
  • Glyphosate*
  • Herbicides* / blood
  • Herbicides* / poisoning
  • Humans
  • Limit of Detection*
  • Reproducibility of Results
  • Spectrometry, Mass, Electrospray Ionization* / methods
  • Tandem Mass Spectrometry* / methods

Substances

  • Glycine
  • Glyphosate
  • Aminobutyrates
  • phosphinothricin
  • Herbicides