Characterization of clinical CSF dynamics and neural axis compliance using the pressure-volume index: I. The normal pressure-volume index

Ann Neurol. 1980 Jun;7(6):508-14. doi: 10.1002/ana.410070603.

Abstract

The pressure-volume index (PVI) technique was used to measure neural axis compliance, cerebrospinal fluid (CSF) formation (If), and CSF absorption (Ro) in 23 children and 7 adults, all free from intracranial masses, who were undergoing diagnostic or therapeutic procedures. Using bolus manipulation of CSF, If was 0.36 +/- 0.08 ml/min and Ro was 2.8 +/- 0.8 mm Hg/ml/min in both adults and children. PVI, as a measure of neural axis compliance or volume buffering capacity, was 25.9 +/- 3.7 ml for the adults. Measured PVI in the children varied from 8.2 to 30.1 ml but correlated well (r = 0.93) with predicted PVI based on estimates of intracranial and spinal volumes obtained from external measurements. This study provides normal reference data in humans for assessing CSF hydrodynamics and neural axis compliance using the PVI technique in pathological settings.