The effect of the prone position on pulmonary mechanics is frame-dependent

Anesth Analg. 1998 Nov;87(5):1175-80. doi: 10.1097/00000539-199811000-00037.

Abstract

By compressing the abdomen and restricting chest wall movement, the prone position compromises pulmonary compliance. For spine surgery, placing the anesthetized patient into the prone position increases the risk of improper ventilation. In this study, we tested the hypothesis that the compromise in pulmonary compliance is related to the patient's body habitus and the surgical frame used to support the patient while in the prone position. Seventy-seven adult patients were divided into three groups according to body mass index: normal (n = 36) < or = 27 kg/m2, heavy (n = 21) 28-31 kg/m2, and obese (n = 20) > or = 32 kg/m2. Patients were placed in the prone position supported by chest rolls, a Wilson frame, or the Jackson spinal surgery table (Jackson table) according to the surgeon's preferences. Peak airway pressure (at the proximal endotracheal tube), pleural pressure (esophageal balloon), and mean arterial pressure were recorded in the supine position and prone position within 15 min of the turn. Dynamic mean (+/- SD) pulmonary compliance (mL/cm H2O) decreased when turning from the supine to the prone position in all three body mass groups when using chest rolls (normal 37+/-5 to 29+/-6; heavy 43+/-2 to 34+/-4; obese 42+/-8 to 32+/-6) or the Wilson frame (normal 39+/-6 to 32+/-7; heavy 43+/-16 to 34+/-10; obese 36+/-11 to 28+/-9). The dynamic pulmonary compliance was not altered in patients positioned on the Jackson table. Regardless of body habitus, using the Jackson table for prone positioning was not associated with a significant alteration in pulmonary or hemodynamic variables. We conclude that moving patients from the supine to the prone position during anesthesia results in a decrease in pulmonary compliance that is frame-dependent but that is not affected by body habitus.

Implications: We hypothesized that compromise in pulmonary compliance in the prone position is related to the patient's body mass index and the surgical frame used. In this study, we demonstrated that prone positioning during anesthesia results in a decrease in pulmonary compliance that is frame-dependent but that is not affected by body mass index.

Publication types

  • Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Female
  • Hemodynamics / physiology
  • Humans
  • Intraoperative Period
  • Male
  • Middle Aged
  • Obesity / physiopathology
  • Prone Position / physiology*
  • Respiratory Function Tests
  • Respiratory Mechanics / physiology*
  • Smoking / physiopathology