Single-copy detection of somatic variants from solid and liquid biopsy

Sci Rep. 2021 Mar 16;11(1):6068. doi: 10.1038/s41598-021-85545-3.

Abstract

Accurate detection of somatic variants, against a background of wild-type molecules, is essential for clinical decision making in oncology. Existing approaches, such as allele-specific real-time PCR, are typically limited to a single target gene and lack sensitivity. Alternatively, next-generation sequencing methods suffer from slow turnaround time, high costs, and are complex to implement, typically limiting them to single-site use. Here, we report a method, which we term Allele-Specific PYrophosphorolysis Reaction (ASPYRE), for high sensitivity detection of panels of somatic variants. ASPYRE has a simple workflow and is compatible with standard molecular biology reagents and real-time PCR instruments. We show that ASPYRE has single molecule sensitivity and is tolerant of DNA extracted from plasma and formalin fixed paraffin embedded (FFPE) samples. We also demonstrate two multiplex panels, including one for detection of 47 EGFR variants. ASPYRE presents an effective and accessible method that simplifies highly sensitive and multiplexed detection of somatic variants.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Circulating Tumor DNA / blood
  • Circulating Tumor DNA / genetics*
  • High-Throughput Nucleotide Sequencing*
  • Humans
  • Liquid Biopsy
  • Mutation*
  • Neoplasms / blood
  • Neoplasms / genetics*
  • Real-Time Polymerase Chain Reaction*

Substances

  • Circulating Tumor DNA