Fluoroacetic acid is a highly polar poison used for rodent control. When ingested by the human body, it seriously damages nerve cells and heart tissues and even causes death by cardiac arrest or respiratory failure. Common detection methods for fluoroacetic acid include gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry, both of which require complex pretreatment methods, such as derivatization. In this study, a method to determine fluoroacetic acid in human blood and urine based on accelerated solvent extraction-ion chromatography-mass spectrometry (ASE-IC-MS) was established. Two pretreatment methods, namely, acetonitrile precipitation and accelerated solvent extraction, were compared. Furthermore, the effects of different extraction conditions, such as the extraction time, extraction temperature, and number of cycles, were investigated. The most suitable chromatographic separation conditions, such as the chromatographic column, column temperature, and elution procedure, were determined, and the MS conditions, such as the collision energy (CE) and declustering potential (DP) of the ion pairs of the target compound, were investigated. Based on the experimental results, the optimal pretreatment methods and detection conditions were obtained, and reliable data were collected. Deionized water was used as the extraction solvent, and blood and urine samples were processed by accelerated solvent extractor. The supernatant was sequentially collected via centrifugal ultrafiltration and 0.22 μm membrane filtration, diluted 50 times, and then injected into the chromatographic column for detection. An Ion Pac AS20 IC column was used for isocratic elution with 15.0 mmol/L KOH solution as the eluent. The effluent was passed through a suppressor and into a triple quadrupole mass spectrometer, which was used to perform MS/MS (ESI-) in multiple reaction monitoring (MRM) mode. The quantitative ion was m/z 77.0>57.0 when the CE and DP were -15.0 eV and -20.0 V, respectively. An external standard method was used for quantitative analysis. The results showed a good linear relationship for fluoroacetic acid in the range of 0.5-500.0 μg/L (r>0.999), with limits of detection (LOD) and quantification (LOQ) of 0.14 and 0.47 μg/L, respectively. The recoveries of fluoroacetic acid in blood and urine were 93.4%-95.8% and 96.2%-98.4%, respectively. The intra-day RSDs for blood and urine were 0.8%-1.6% and 0.2%-1.0%, respectively, while the inter-day RSDs were 2.3%-3.8% and 3.9%-6.9%, respectively. Further investigation revealed that the matrix effects of this method in blood and urine, at -7.4% and -3.0%, respectively, were fairly weak. The established method was successfully applied to detect fluoroacetic acid in human blood and urine obtained from a poisoning case, and the results obtained provided crucial clues that led to swift case resolution. The efficiency of the method was significantly higher than that of conventional detection methods. In conclusion, the developed method has high sensitivity and good repeatability and is suitable for the rapid detection of fluoroacetic acid in human blood and urine. Moreover, because this method does not require derivatization, it is simple and efficient.

建立了快速溶剂萃取-离子色谱-质谱法测定人体血液、尿液中氟乙酸的方法。以去离子水为萃取溶剂,使用快速溶剂萃取仪处理血液和尿液样品,取上清液依次经超滤管和0.22 μm水相针式滤膜净化,稀释50倍后进样检测。采用Ion Pac AS20离子色谱柱以15.0 mmol/L的KOH溶液为淋洗液进行等度淋洗,流出液通过抑制器后进入三重四极杆质谱,在负离子、多反应监测模式下检测,外标法定量。结果表明,氟乙酸在0.5~500.0 μg/L范围内线性关系良好(r>0.999),检出限和定量限分别为0.14、0.47 μg/L。氟乙酸在血液和尿液中的回收率分别为93.4%~95.8%、96.2%~98.4%,日内精密度分别为0.8%~1.6%、0.2%~1.0%,日间精密度分别为2.3%~3.8%、3.9%~6.9%。进一步考察发现该方法在血液、尿液中的基质效应较弱,分别为-7.4%、-3.0%。该法无需衍生化处理,简便高效,灵敏度高,重复性好,适用于人体血液、尿液中氟乙酸的快速检测。

Keywords: accelerated solvent extraction (ASE); blood; centrifugal ultrafiltration; fluoroacetic acid; ion chromatography-tandem mass spectrometry (IC-MS/MS); urine.

Publication types

  • English Abstract

MeSH terms

  • Chromatography, High Pressure Liquid
  • Fluoroacetates*
  • Gas Chromatography-Mass Spectrometry
  • Humans
  • Spectrum Analysis
  • Tandem Mass Spectrometry*

Substances

  • fluoroacetic acid
  • Fluoroacetates