Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1981 2
1982 1
1991 2
1992 1
1994 1
2000 1
2002 1
2006 2
2007 2
2011 1
2012 1
2014 4
2015 2
2018 2
2019 2
2020 1
2021 2
2022 5
2023 4
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

35 results

Results by year

Filters applied: . Clear all
Page 1
Does Intravenous Lactated Ringer's Solution Raise Serum Lactate?
Zitek T, Skaggs ZD, Rahbar A, Patel J, Khan M. Zitek T, et al. Among authors: skaggs zd. J Emerg Med. 2018 Sep;55(3):313-318. doi: 10.1016/j.jemermed.2018.05.031. Epub 2018 Jul 20. J Emerg Med. 2018. PMID: 30037514 Clinical Trial.
Lactated Ringer's solution (LR) is used in the resuscitation of septic patients and contains 28 mmol/L of sodium lactate. OBJECTIVES: We sought to determine if a bolus of 30 mL/kg of LR increases serum lactate levels. ...RESULTS: After 30 mL/kg of intravenous LR, the mean …
Lactated Ringer's solution (LR) is used in the resuscitation of septic patients and contains 28 mmol/L of sodium lactate. OBJECTIVES: …
Comparison of Breath- and Blood-Alcohol Concentrations in a Controlled Drinking Study.
Skaggs L, Heizler A, Kalscheur D, Miles A, Barkholtz HM. Skaggs L, et al. J Anal Toxicol. 2022 Jul 14;46(6):683-688. doi: 10.1093/jat/bkab086. J Anal Toxicol. 2022. PMID: 34320180
In this work, 114 volunteers were dosed with 80-proof liquor to produce peak blood-alcohol concentration (BAC) or breath-alcohol concentration (BrAC) of 0.040-0.080 g/100 mL blood or g/210 L breath. This was followed by a 30 minute deprivation period before simultaneous bl …
In this work, 114 volunteers were dosed with 80-proof liquor to produce peak blood-alcohol concentration (BAC) or breath-alcohol concentrati …
The Prevalence of Opioids in US Drinking Water Sources Detected Using Direct-Injection High-Performance Liquid Chromatography-Tandem Mass Spectrometry.
Skaggs CS, Logue BA. Skaggs CS, et al. Environ Toxicol Chem. 2022 Nov;41(11):2658-2666. doi: 10.1002/etc.5453. Epub 2022 Sep 13. Environ Toxicol Chem. 2022. PMID: 35920352
Drinking water samples (10 ml) are simply syringe-filtered and then analyzed by HPLC-MS/MS. A wide linear range (0.25-100 ng/L) and ultratrace limits of detection (80, 150, and 500 pg/L for fentanyl, hydrocodone, and codeine, respectively) were features of the metho …
Drinking water samples (10 ml) are simply syringe-filtered and then analyzed by HPLC-MS/MS. A wide linear range (0.25-100 ng/L) and u …
Ultratrace analysis of per- and polyfluoroalkyl substances in drinking water using ice concentration linked with extractive stirrer and high performance liquid chromatography - tandem mass spectrometry.
Skaggs CS, Logue BA. Skaggs CS, et al. J Chromatogr A. 2021 Dec 6;1659:462493. doi: 10.1016/j.chroma.2021.462493. Epub 2021 Aug 25. J Chromatogr A. 2021. PMID: 34706316
The method featured a relatively low sample volume requirement (10 mL), automated extraction, minimal matrix effects, and minimal organic solvent use (i.e., the method requires only 50 L of methanol per sample). The method produced a wide linear range of 0.5 to 500 ng/L
The method featured a relatively low sample volume requirement (10 mL), automated extraction, minimal matrix effects, and minimal organic so …
Reliability of Preoperative Supine Versus Bending Radiographs in Estimating the Structural Nature of Curves in EOS.
Skaggs KF, Bainton NM, Boby AZ, Rymond CC, Fields MW, Roye BD, Vitale MG. Skaggs KF, et al. J Pediatr Orthop. 2023 Feb 1;43(2):70-75. doi: 10.1097/BPO.0000000000002305. Epub 2022 Dec 1. J Pediatr Orthop. 2023. PMID: 36607916
Coronal parameters included: proximal thoracic (PT) curve, main thoracic (MT) curve, and thoracolumbar/lumbar (TL/L) curve. Each radiograph was measured twice by 2 different raters. ...Supine PT and MT curve measurements were highly associated with corresponding side-bendi …
Coronal parameters included: proximal thoracic (PT) curve, main thoracic (MT) curve, and thoracolumbar/lumbar (TL/L) curve. Each radi …
35 results