Acromion morphology is associated with glenoid bone loss in posterior glenohumeral instability

J Shoulder Elbow Surg. 2023 Sep;32(9):1850-1856. doi: 10.1016/j.jse.2023.03.005. Epub 2023 Mar 30.

Abstract

Background: The acromion morphology in a shoulder with posterior instability differs from that of a shoulder without glenohumeral instability. Specifically, the acromion with a flatter sagittal tilt, greater posterior acromial height, and less posterior coverage is associated with posterior instability. However, the association between acromion morphology and glenoid bone loss (GBL) in the setting of posterior glenohumeral instability has not previously been investigated. The purpose of this study was to determine whether acromial morphology influences the extent or pattern of posterior GBL in a cohort of patients with posterior glenohumeral instability.

Methods: This multicenter retrospective study identified 89 shoulders with unidirectional posterior glenohumeral instability. Total area GBL was measured using the best-fit circle method on magnetic resonance imaging (MRI). Shoulders were divided into 3 groups: (1) no GBL (n = 30), (2) GBL 0%-13.5% (n = 45), or (3) GBL ≥13.5% (n = 14). Acromion measurements were performed on MRI and included acromial tilt, posterior acromial height, anterior acromial coverage, and posterior acromial coverage.

Results: Patients without GBL had a steeper acromial tilt (58.5° ± 1.4°) compared with those with 0%-13.5% GBL (64.3° ± 1.5°) or GBL ≥13.5% (67.7° ± 1.8°) (P = .004). Patients without GBL also had greater posterior coverage (65.4° ± 1.7°) compared with those with GBL (60.3° ± 1.4°) (P = .015). Posterior acromion height was not significantly different among groups.

Conclusion: The results demonstrate that an acromion with a flatter sagittal tilt and less posterior coverage is associated with GBL in the setting of posterior glenohumeral instability. This is important to consider as posterior GBL has been identified as a risk factor for failure of posterior soft tissue-stabilizing procedures.

Keywords: Shoulder; acromion; acromion morphology; glenohumeral instability; glenoid bone loss; posterior shoulder instability.

Publication types

  • Multicenter Study

MeSH terms

  • Acromion / diagnostic imaging
  • Acromion / pathology
  • Bone Diseases, Metabolic*
  • Humans
  • Joint Instability* / diagnostic imaging
  • Joint Instability* / pathology
  • Retrospective Studies
  • Shoulder Joint* / diagnostic imaging
  • Shoulder Joint* / pathology
  • Tomography, X-Ray Computed