Using GFP in FRET-based applications
- PMID: 10087619
- DOI: 10.1016/s0962-8924(98)01434-2
Using GFP in FRET-based applications
Abstract
The use of green fluorescent protein (GFP) is a powerful technology that has recently enabled investigators to study dynamic molecular events within living cells. One method for detecting molecular interactions involves fluorescence resonance energy transfer (FRET) between two GFPs or between GFP and a second fluorophore. This review summarizes the use of GFP for FRET and illustrates the theme with specific examples on how GFP has been employed as an intracellular molecular sensor.
Similar articles
-
A protease assay for two-photon crosscorrelation and FRET analysis based solely on fluorescent proteins.Proc Natl Acad Sci U S A. 2002 Sep 17;99(19):12161-6. doi: 10.1073/pnas.192433499. Epub 2002 Sep 3. Proc Natl Acad Sci U S A. 2002. PMID: 12209012 Free PMC article.
-
Imaging FRET between spectrally similar GFP molecules in single cells.Nat Biotechnol. 2001 Feb;19(2):167-9. doi: 10.1038/84443. Nat Biotechnol. 2001. PMID: 11175733
-
Protease-sensitive signalling by chemically engineered intramolecular fluorescent resonance energy transfer mutants of green fluorescent protein.Biochim Biophys Acta. 2004 Sep 17;1679(3):222-9. doi: 10.1016/j.bbaexp.2004.06.009. Biochim Biophys Acta. 2004. PMID: 15358514
-
Imaging signal transduction in living cells with GFP-based probes.IUBMB Life. 2000 May;49(5):375-9. doi: 10.1080/152165400410218. IUBMB Life. 2000. PMID: 10902568 Review.
-
Role of green fluorescent proteins and their variants in development of FRET-based sensors.J Biosci. 2018 Sep;43(4):763-784. J Biosci. 2018. PMID: 30207321 Review.
Cited by
-
Correlating calcium binding, Förster resonance energy transfer, and conformational change in the biosensor TN-XXL.Biophys J. 2012 May 16;102(10):2401-10. doi: 10.1016/j.bpj.2012.03.065. Epub 2012 May 15. Biophys J. 2012. PMID: 22677394 Free PMC article.
-
Imaging molecular interactions in living cells.Mol Endocrinol. 2005 Jul;19(7):1675-86. doi: 10.1210/me.2005-0028. Epub 2005 Mar 10. Mol Endocrinol. 2005. PMID: 15761028 Free PMC article. Review.
-
TCR mispairing in genetically modified T cells was detected by fluorescence resonance energy transfer.Mol Biol Rep. 2010 Dec;37(8):3951-6. doi: 10.1007/s11033-010-0053-y. Epub 2010 Apr 6. Mol Biol Rep. 2010. PMID: 20373027
-
Visualization of small GTPase activity with fluorescence resonance energy transfer-based biosensors.Nat Protoc. 2009;4(11):1623-31. doi: 10.1038/nprot.2009.175. Epub 2009 Oct 15. Nat Protoc. 2009. PMID: 19834477
-
Detection of infective poliovirus by a simple, rapid, and sensitive flow cytometry method based on fluorescence resonance energy transfer technology.Appl Environ Microbiol. 2010 Jan;76(2):584-8. doi: 10.1128/AEM.01851-09. Epub 2009 Nov 20. Appl Environ Microbiol. 2010. PMID: 19933336 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
