Background: Long-segment colon interposition has been used for esophageal replacement for acquired esophageal disease. The indications for use, morbidity, and functional results of these conduits have been debated.
Methods: We reviewed the medical records, office visits, and operative reports of patients undergoing long colon interposition for acquired esophageal disease at our institution from 1956 to 1997.
Results: Long colon interposition was performed in 52 patients for caustic injury (n = 20), gastroesophageal disease (n = 16), previous irradiation (n = 8), primary motility disorders (n = 4), and acquired absence of the esophagus (n = 4). From 1976 to 1997, acquired diseases accounted for 62% of long colon interposition. The left colon was used in 46 patients and the right colon in 6. The in-hospital mortality rate was 4%. Early complications included graft ischemia in 5 patients, anastomotic leak in 3, and small bowel obstruction in 1. Late complications included anastomotic stenosis requiring dilation in 26 patients, with 2 requiring surgical revision, and bile reflux requiring surgical diversion in 1 patient. Swallowing function was excellent in 24% of patients, good in 66%, and poor in 10%.
Conclusions: Long colon interposition can be performed safely, with acceptable long-term functional results in patients with acquired esophageal disease.