Evaluation of HIV serial and parallel serologic testing algorithms in Abidjan, Côte d'Ivoire
- PMID: 10207552
- DOI: 10.1097/00002030-199901140-00015
Evaluation of HIV serial and parallel serologic testing algorithms in Abidjan, Côte d'Ivoire
Abstract
Objective: To evaluate HIV serologic testing algorithms based on a combination of three enzyme linked immunosorbent assays (ELISA) for the confirmation of HIV infection in Abidjan, Côte d'Ivoire, where HIV-2 and HIV-1 non-B subtypes are prevalent.
Methods: A total of 1069 human sera with known serologic status, in addition to a seroconversion and low titer antibody panel were initially tested by six ELISA to determine the sensitivity, specificity and delta values of the assays. On the basis of the performance of the assays, three ELISA (Enzygnost, ICE 1.0.2, and Vironostika) were selected for use in a parallel and serial testing algorithm in analyzing 8283 consecutively collected sera. In the parallel testing algorithm, sera concordantly reactive or non-reactive by Enzygnost and ICE 1.0.2 were considered as true positive or true negative, respectively. In the serial algorithm, sera reactive by Enzygnost were retested by ICE 1.0.2. Sera with discordant results were tested by Vironostika, and the results was considered definitive. All reactive sera, plus a random sample of negative sera were tested for confirmation by Peptilav. In addition, a random sample of reactive sera was tested by Western blot.
Results: All ELISA had 100% sensitivity; specificities ranged from 96.8 to 100%. Positive and negative delta values of the ELISA were high (range, 6.89 to 46.07 and -2.05 to -5.75, respectively). Of the 8283 sera, 2054 were considered true positives and were correctly classified by the parallel testing algorithm (sensitivity, 100%). Of the 6229 true negative sera, 6226 were negative by the parallel testing algorithm (specificity, 99.95%). The sensitivity of the serial algorithm was 99.96%, and specificity was 99.95%. None of the 250 concordant ELISA-negative sera in the algorithm that were randomly tested in Peptilav was positive; similarly, all of the 103 concordant ELISA-positive sera were confirmed by Western blot. The three-ELISA algorithm resulted in reagent cost-savings of at least 50% compared with the Peptilav-based algorithm.
Conclusion: These results suggest that a combination of ELISA using different principles or antigens in a serial or parallel algorithm is an efficient and cost-effective alternative to the standard algorithm in areas where HIV-1 and HIV-2 are prevalent.
Similar articles
-
Performance of six commercial enzyme immunoassays and two alternative HIV-testing algorithms for the diagnosis of HIV-1 infection in Kisumu, Western Kenya.J Virol Methods. 2011 Sep;176(1-2):24-31. doi: 10.1016/j.jviromet.2011.05.021. Epub 2011 May 27. J Virol Methods. 2011. PMID: 21635920
-
Sensitivity and specificity of human immunodeficiency virus rapid serologic assays and testing algorithms in an antenatal clinic in Abidjan, Ivory Coast.J Clin Microbiol. 2001 May;39(5):1808-12. doi: 10.1128/JCM.39.5.1808-1812.2001. J Clin Microbiol. 2001. PMID: 11325995 Free PMC article.
-
Field evaluation of alternative testing strategies for diagnosis and differentiation of HIV-1 and HIV-2 infections in an HIV-1 and HIV-2-prevalent area.AIDS. 1997 Dec;11(15):1815-22. doi: 10.1097/00002030-199715000-00005. AIDS. 1997. PMID: 9412699
-
Rapid and simple screening and supplemental testing for HIV-1 and HIV-2 infections in west Africa.AIDS. 1993 Jun;7(6):883-5. doi: 10.1097/00002030-199306000-00019. AIDS. 1993. PMID: 8395857
-
Field evaluation of a combination of monospecific enzyme-linked immunosorbent assays for type-specific diagnosis of human immunodeficiency virus type 1 (HIV-1) and HIV-2 infections in HIV-seropositive persons in Abidjan, Ivory Coast.J Clin Microbiol. 1998 Jan;36(1):123-7. doi: 10.1128/JCM.36.1.123-127.1998. J Clin Microbiol. 1998. PMID: 9431934 Free PMC article.
Cited by
-
A Dire Presentation of Carcinoma Cervix in a Human Immunodeficiency Virus-Positive Case: A Salient Display.Cureus. 2023 Sep 20;15(9):e45605. doi: 10.7759/cureus.45605. eCollection 2023 Sep. Cureus. 2023. PMID: 37868493 Free PMC article.
-
Field evaluation of the gag-based heteroduplex mobility assay for genetic subtyping of circulating recombinant forms of human immunodeficiency virus type 1 in Abidjan, Côte d'Ivoire.J Clin Microbiol. 2003 Jul;41(7):3056-9. doi: 10.1128/JCM.41.7.3056-3059.2003. J Clin Microbiol. 2003. PMID: 12843043 Free PMC article.
-
Assessment of CD8 T cell immune activation markers to monitor response to antiretroviral therapy among HIV-1 infected patients in Côte d'Ivoire.Clin Exp Immunol. 2005 Apr;140(1):138-48. doi: 10.1111/j.1365-2249.2005.02734.x. Clin Exp Immunol. 2005. PMID: 15762885 Free PMC article.
-
Evaluation of nine HIV rapid test kits to develop a national HIV testing algorithm in Nigeria.Afr J Lab Med. 2015 May 29;4(1):1-17. doi: 10.4102/ajlm.v4i1.224. eCollection 2015. Afr J Lab Med. 2015. PMID: 38440307 Free PMC article.
-
HIV serologically indeterminate individuals: Future HIV status and risk factors.PLoS One. 2020 Aug 26;15(8):e0237633. doi: 10.1371/journal.pone.0237633. eCollection 2020. PLoS One. 2020. PMID: 32845933 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
