Quantitative in situ determination of conjugative gene transfer in defined bacterial biofilms using automated confocal laser scanning microscopy followed by three-dimensional analysis of cellular biovolumes revealed conjugation rates 1,000-fold higher than those determined by classical plating techniques. Conjugation events were not affected by nutrient concentration alone but were influenced by time and biofilm structure.