Relative potencies of bupivacaine and ropivacaine for analgesia in labour

Br J Anaesth. 1999 Mar;82(3):371-3. doi: 10.1093/bja/82.3.371.

Abstract

We have used the technique of randomized, double-blind sequential allocation to compare the minimum local analgesic concentrations (MLAC) of epidural bupivacaine and ropivacaine for women in the first stage of labour. The test bolus was 20 ml of local anaesthetic solution. The concentration was determined by the response of the previous woman to a higher or lower concentration of local anaesthetic, according to up-down sequential allocation. Efficacy was assessed using a 100-mm visual analogue pain score (VAPS). The test solution had to achieve a VAPS of 10 mm or less to be judged effective. For bupivacaine, MLAC was 0.093 (95% CI 0.076-0.110)% w/v, and for ropivacaine, 0.156 (95% CI 0.136-0.176)%w/v (P < 0.0001, 95% CI difference 0.036-0.090). The analgesic potency of ropivacaine was 0.60 (0.47-0.75) relative to bupivacaine. Claims for reduced toxicity and motor block must be considered with differences in analgesic potency in mind.

Publication types

  • Clinical Trial
  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Adult
  • Amides*
  • Analgesia, Epidural / methods*
  • Analgesia, Obstetrical / methods*
  • Anesthetics, Local*
  • Bupivacaine*
  • Dose-Response Relationship, Drug
  • Double-Blind Method
  • Female
  • Humans
  • Pain Measurement
  • Pregnancy
  • Ropivacaine