Reactive oxygen species (ROS) production and the outcome of diagnostic tests of sperm function

Int J Androl. 1999 Aug;22(4):236-42. doi: 10.1046/j.1365-2605.1999.00174.x.

Abstract

Washed sperm suspensions from 64 out of 89 (72%) randomly selected infertility patients produced detectable reactive oxygen species (ROS) compared to 17 out of 67 (25%) prospective semen donors (p < 0.01, Chi-square test). Among patients, the median sperm concentration in ejaculates which yielded sperm suspensions that generated detectable levels of ROS was lower than in those which did not: 36.2 (15.63-57.64) vs. 71.5 (22-108) x 10(6)/mL, respectively (median (interquartile range), p < 0.05, Kruskal-Wallis test). In samples that produced ROS, the basal rate of production and the rates after stimulation with 50 mumol N-formyl met leu phe (N-FMLP) l-1 or with 100 nmol phorbol 12-myristate 13-acetate (PMA) l-1 were significantly and inversely correlated with sperm concentration in the ejaculate (r = -0.43, -0.41 and -0.35, respectively, p < 0.01 Spearman's rank correlation). The rate of ROS production showed no relationship to the motility of spermatozoa in semen, whether evaluated visually or via computer assisted semen analysis. However, there was a significant negative correlation (r = -0.370) between the motile, normal sperm concentration (MNSC) and basal ROS production, and when stimulated with N-FMLP (r = -0.311) or with PMA (r = -0.249) (all p < 0.05). In patient samples that generated detectable ROS, the ability of the spermatozoa to retain motility for 24 h after preparation on a 40/80% Percoll gradient was negatively correlated with basal ROS production (r = -0.310, p < 0.05). ROS production was also related to the outcome of in vitro sperm mucus penetration tests. Unstimulated levels of ROS production showed a significant (p < 0.05), negative correlation with the number of progressively motile spermatozoa present in mucus after 15 (r = -0.379) and 60 (r = -0.362) min. These results suggest that sperm samples with increased ROS tend to have poor semen quality and reduced performance in a number of routine, diagnostic sperm function tests.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Autoantibodies / analysis
  • Autoantibodies / immunology
  • Cell Survival
  • Cervix Mucus / physiology
  • Cervix Uteri / physiology
  • Female
  • Humans
  • Infertility, Male / metabolism
  • Male
  • Reactive Oxygen Species / metabolism*
  • Reference Values
  • Sperm Motility
  • Spermatozoa / immunology
  • Spermatozoa / metabolism
  • Spermatozoa / physiology*

Substances

  • Autoantibodies
  • Reactive Oxygen Species