Functional assessment of chest wall integrity after methylmethacrylate reconstruction

Ann Thorac Surg. 2000 Mar;69(3):919-23. doi: 10.1016/s0003-4975(99)01422-8.

Abstract

Background: All patients with extensive resection of the anterolateral chest wall and the sternum followed by reconstruction with methylmethacrylate substitutes were assessed prospectively 6 months after the operation to delineate chest wall integrity with pulmonary function and cine-magnetic resonance imaging.

Methods: Twenty-six patients underwent chest wall reconstruction by use of methylmethacrylate between 1994 and 1998 due to primary tumors in 35%, metastases in 27%, T3 lung cancer in 19%, and debridement for radionecrosis and osteomyelitis in 19% of patients. Three to eight ribs were resected and additional sternum resection was performed in 39% of patients.

Results: There was no 30-day mortality. All patients were extubated after the operation without need for reintubation. Prosthesis dislocation occurred in 1 patient and infection in 2 patients during follow-up. Nineteen patients (73%) suffered no restrictions of daily activities. Clinical examination revealed normal shoulder girdle function in 77% of patients. There was no significant difference between preoperative and postoperative FEV1 (forced expiratory volume in 1 second) measurements in patients with lobectomy or wedge resections. Cinemagnetic resonance imaging revealed concordant chest wall movements during respiration in 92% of patients without paradoxical movements or implant dislocations being observed.

Conclusions: Large defects of the anterolateral chest wall and sternum can be reconstructed efficiently with methylmethacrylate substitutes with minimal morbidity and excellent cosmetic and functional outcome.

Publication types

  • Clinical Trial

MeSH terms

  • Adult
  • Aged
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Methylmethacrylate*
  • Middle Aged
  • Plastic Surgery Procedures / methods*
  • Prospective Studies
  • Prostheses and Implants*
  • Recovery of Function
  • Thoracic Surgical Procedures / methods*

Substances

  • Methylmethacrylate