Robust multiresolution alignment of MRI brain volumes
- PMID: 10800036
- DOI: 10.1002/(sici)1522-2594(200005)43:5<705::aid-mrm13>3.0.co;2-r
Robust multiresolution alignment of MRI brain volumes
Abstract
An algorithm for the automatic alignment of MRI volumes of the human brain was developed, based on techniques adopted from the computer vision literature for image motion estimation. Most image registration techniques rely on the assumption that corresponding voxels in the two volumes have equal intensity, which is not true for MRI volumes acquired with different coils and/or pulse sequences. Intensity normalization and contrast equalization were used to minimize the differences between the intensities of the two volumes. However, these preprocessing steps do not correct perfectly for the image differences when using different coils and/or pulse sequences. Hence, the alignment algorithm relies on robust estimation, which automatically ignores voxels where the intensities are sufficiently different in the two volumes. A multiresolution pyramid implementation enables the algorithm to estimate large displacements. The resulting algorithm is used routinely to align MRI volumes acquired using different protocols (3D SPGR and 2D fast spin echo) and different coils (surface and head) to subvoxel accuracy (better than 1 mm).
Copyright 2000 Wiley-Liss, Inc.
Similar articles
-
Histogram-based normalization technique on human brain magnetic resonance images from different acquisitions.Biomed Eng Online. 2015 Jul 28;14:73. doi: 10.1186/s12938-015-0064-y. Biomed Eng Online. 2015. PMID: 26215471 Free PMC article.
-
Fast and robust registration of PET and MR images of human brain.Neuroimage. 2004 May;22(1):434-42. doi: 10.1016/j.neuroimage.2004.01.016. Neuroimage. 2004. PMID: 15110036
-
Robust image registration for functional magnetic resonance imaging of the brain.Med Biol Eng Comput. 2001 Sep;39(5):517-24. doi: 10.1007/BF02345141. Med Biol Eng Comput. 2001. PMID: 11712647
-
Retrospective registration of PET and MR brain images: an algorithm and its stereotactic validation.J Comput Assist Tomogr. 1994 Sep-Oct;18(5):800-10. doi: 10.1097/00004728-199409000-00021. J Comput Assist Tomogr. 1994. PMID: 8089332
-
An investigation of the effect of fat suppression and dimensionality on the accuracy of breast MRI segmentation using U-nets.Med Phys. 2019 Mar;46(3):1230-1244. doi: 10.1002/mp.13375. Epub 2019 Feb 4. Med Phys. 2019. PMID: 30609062
Cited by
-
Mapping human somatosensory cortex in individual subjects with 7T functional MRI.J Neurophysiol. 2010 May;103(5):2544-56. doi: 10.1152/jn.01017.2009. Epub 2010 Feb 17. J Neurophysiol. 2010. PMID: 20164393 Free PMC article.
-
MRI Metrics of Cerebral Endothelial Cell-Derived Exosomes for the Treatment of Cognitive Dysfunction Induced in Aging Rats Subjected to Type 2 Diabetes.Diabetes. 2022 May 1;71(5):873-880. doi: 10.2337/db21-0754. Diabetes. 2022. PMID: 35175337 Free PMC article.
-
Response suppression in v1 agrees with psychophysics of surround masking.J Neurosci. 2003 Jul 30;23(17):6884-93. doi: 10.1523/JNEUROSCI.23-17-06884.2003. J Neurosci. 2003. PMID: 12890783 Free PMC article.
-
Avoiding asymmetry-induced bias in longitudinal image processing.Neuroimage. 2011 Jul 1;57(1):19-21. doi: 10.1016/j.neuroimage.2011.02.076. Epub 2011 Mar 3. Neuroimage. 2011. PMID: 21376812 Free PMC article.
-
Asymmetries between achromatic and chromatic extraction of 3D motion signals.Proc Natl Acad Sci U S A. 2019 Jul 2;116(27):13631-13640. doi: 10.1073/pnas.1817202116. Epub 2019 Jun 17. Proc Natl Acad Sci U S A. 2019. PMID: 31209058 Free PMC article.