Consistency in the amount of linear polymerization shrinkage in syringe-type composites

Dent Mater. 1999 Nov;15(6):442-6. doi: 10.1016/s0109-5641(99)00072-x.

Abstract

Objectives: The purpose of this study was to investigate whether the composite resin in a syringe showed a consistent shrinkage through its content. Additionally, the amount of linear shrinkage was compared between materials.

Methods: Five brands of syringe-type and one brand of carpule-type composite resins were used in this study. To each brand, two to three syringes were assigned. In the carpule-type composite, 15 carpules were used. The linear polymerization shrinkage was measured using a custom-made linometer. In this linometer, the amount of displacement of an aluminum disk, which was caused by the linear shrinkage of composite resin, was recorded by a computer every second for 90 s.

Results: The syringe-type composites showed similar consistencies in the amount of linear shrinkage except one. The linear shrinkage of the carpule-type Tetric Ceram showed more consistency compared with syringe-type composites. The amount of linear polymerization shrinkage varied between materials.

Significance: This investigation demonstrates that the use of carpule-type composites is recommended instead of syringe-types, because of the consistency in its linear shrinkage. The custom-made linometer provides an effective way to study polymerization shrinkage.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Analysis of Variance
  • Composite Resins / chemistry*
  • Materials Testing / instrumentation
  • Pharmaceutical Vehicles
  • Polymers / chemistry
  • Syringes

Substances

  • Composite Resins
  • Pharmaceutical Vehicles
  • Polymers