Investigation of the prevalence of Legionella species in domestic hot water systems

N Z Med J. 2000 Jun 9;113(1111):218-20.

Abstract

Aims: To investigate the prevalence of Legionella spp. in the hot water systems of a representative sample of Wellington domestic residences with electrically heated hot water systems, and to investigate risk factors (eg water temperature, plumbing materials) for such contamination.

Method: 100 households with electrically heated hot water systems in the Wellington area were investigated. Samples of hot water from several hot water outlets were collected, and characteristics of the plumbing system were recorded. Water samples and swabs were cultured and further examined by polymerase chain reaction (PCR) and direct fluorescence antibody (DFA) testing to identify Legionella spp. and serogroups.

Results: No Legionella spp. were isolated by culture. PCR tested positive for Legionella in specimens from twelve residences. Six of these were also positive by DFA testing. The only environmental factor found to be associated with the presence of Legionella was recent plumbing work on the hot water system. Five of the twelve PCR-positive residences, and four of the six DFA-confirmed residences had hot water delivery temperatures in excess of 60 degrees C.

Conclusions: The results suggest that either Legionellae colonise domestic hot water reticulation systems and/or that the organisms are killed during passage through the hot water tank. Both possibilities may be correct. Further work to characterise the microbial ecology of Legionella-positive hot water distribution systems would be useful, as would the development of improved methods for culturing the organisms from potable water.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Humans
  • Legionella / isolation & purification*
  • New Zealand
  • Polymerase Chain Reaction
  • Sensitivity and Specificity
  • Water Microbiology*
  • Water Supply*