Prevention of pin track infection in external fixation with silver coated pins: clinical and microbiological results
- PMID: 10984710
- DOI: 10.1002/1097-4636(200009)53:5<600::aid-jbm21>3.0.co;2-d
Prevention of pin track infection in external fixation with silver coated pins: clinical and microbiological results
Abstract
Pin tract infection is a frequent complication of external fixation; according to literature its frequency ranges from 2-30%. The recent introduction of silver coating of polymeric materials was found to decrease bacterial adhesion; its clinical use with Foley catheters and central venous catheters led to significant results. To verify the ability of the same silver coating to decrease the bacterial colonization on external fixation screws, a prospective randomized study was carried out on 24 male patients; a total of 106 screws were implanted in the lower limb to fix femoral or tibial diaphyseal fractures: 50 were coated with silver and 56 were commercially available stainless steel screws. Although the coated screws resulted in a lower rate of positive cultures (30.0%) than the uncoated screws (42.9%), this difference was not statistically significant (p = 0.243). The clinical behavior of the coated screws did not differ from that of the uncoated ones. Furthermore, the implant of silver-coated screws resulted in a significant increase in the silver serum level. These results led us to consider it ethically unacceptable to continue this investigation.
Copyright 2000 John Wiley & Sons, Inc.
Similar articles
-
Pin tract infections: silver vs uncoated pins.Orthopedics. 1994 May;17(5):445-8. doi: 10.3928/0147-7447-19940501-11. Orthopedics. 1994. PMID: 8036188
-
The effects of silver coated external fixation pins.Iowa Orthop J. 2006;26:48-53. Iowa Orthop J. 2006. PMID: 16789449 Free PMC article. Clinical Trial.
-
Fixation strength and pin tract infection of hydroxyapatite-coated tapered pins.Clin Orthop Relat Res. 2001 Jul;(388):209-17. doi: 10.1097/00003086-200107000-00029. Clin Orthop Relat Res. 2001. PMID: 11451122 Clinical Trial.
-
Hydroxyapatite-coated external fixation pins.Expert Rev Med Devices. 2005 Jul;2(4):465-71. doi: 10.1586/17434440.2.4.465. Expert Rev Med Devices. 2005. PMID: 16293085 Review.
-
The use of gentamicin-coated nails in complex open tibia fracture and revision cases: A retrospective analysis of a single centre case series and review of the literature.Injury. 2015 Dec;46(12):2433-7. doi: 10.1016/j.injury.2015.09.028. Epub 2015 Oct 8. Injury. 2015. PMID: 26477343 Review.
Cited by
-
Potential side effects of antibacterial coatings in orthopaedic implants: A systematic review of clinical studies.Front Bioeng Biotechnol. 2023 Feb 9;11:1111386. doi: 10.3389/fbioe.2023.1111386. eCollection 2023. Front Bioeng Biotechnol. 2023. PMID: 36845182 Free PMC article.
-
Hydroxyapatite-coated compared with stainless steel external fixation pins did not show impact in the rate of pin track infection: a multicenter prospective study.Int Orthop. 2023 May;47(5):1163-1169. doi: 10.1007/s00264-023-05717-w. Epub 2023 Feb 11. Int Orthop. 2023. PMID: 36773051 Free PMC article. Clinical Trial.
-
Fungal-derived selenium nanoparticles and their potential applications in electroless silver coatings for preventing pin-tract infections.Regen Biomater. 2022 Feb 22;9(1):rbac013. doi: 10.1093/rb/rbac013. eCollection 2022. Regen Biomater. 2022. PMID: 35449828 Free PMC article.
-
The Potential of Drug Delivery Nanosystems for Sepsis Treatment.J Inflamm Res. 2021 Dec 19;14:7065-7077. doi: 10.2147/JIR.S339113. eCollection 2021. J Inflamm Res. 2021. PMID: 34984019 Free PMC article. Review.
-
Role of coatings and materials of external fixation pins on the rates of pin tract infection: A systematic review and meta-analysis.World J Orthop. 2021 Nov 18;12(11):920-930. doi: 10.5312/wjo.v12.i11.920. eCollection 2021 Nov 18. World J Orthop. 2021. PMID: 34888152 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical