Acetabular component orientation as an indicator of implant luxation in cemented total hip arthroplasty
- PMID: 11098784
- DOI: 10.1053/jvet.2000.17856
Acetabular component orientation as an indicator of implant luxation in cemented total hip arthroplasty
Abstract
Objective: To determine the sensitivity and specificity with which acetabular component angles of inclination and version could be used, alone or in combination, to predict luxation of cemented total hip arthroplasties (THA).
Study design: Comparison of retrospectively selected cases and controls
Sample population: All THA performed at the University of Florida between 1991 and 1998 with the BioMedtrix system and for which at least 2 months of radiographic follow-up were available. All THA performed at the University of Georgia with the BioMedtrix system which subsequently luxated.
Methods: Acetabular component inclination angle (IA) and acetabular version angle (VA) were determined for each THA. Data were grouped according to outcome - luxation or no luxation - with the luxated cases from the 2 institutions pooled. Receiver operator characteristic (ROC) analysis was used to evaluate decision rules for using IA and VA as tests for detecting postoperative luxation. Sensitivity and specificity for luxation and 95% confidence bounds were computed with selected values of IA and VA as cut-points.
Results: The nonluxation group consisted of 68 THA with a median follow-up time of 5 months (range, 2-60 months). The luxation group consisted of 12 THA with a mean time to luxation of 36 days. The nonluxation group had a mean +/- standard deviation (SD) IA and VA of 40.3 degrees +/- 8.9 degrees and 71.1 +/- 13.6 degrees, respectively, whereas the luxation group had a mean +/- SD IA and VA of 34.7 degrees +/- 12.6 degrees and 72.9 degrees +/- 16.6 degrees, respectively. An IA cut-point of 37.8 degrees achieved 58.3% sensitivity and 57.4% specificity. A VA cut-point of 73 degrees achieved 75.0% sensitivity and 51.5% specificity. IA and VA considered simultaneously achieved a 50.0% sensitivity and 88.2% specificity.
Conclusions and clinical relevance: ROC analysis indicated that both IA and VA considered individually or simultaneously were poor indicators of luxation. Although extreme values of IA may predict luxation with high specificity, the potential for luxation cannot be excluded based on apparently appropriate values of IA and VA. The results of this study also indicate that a successful outcome is possible with a wide range of acetabular component positions.
Similar articles
-
Evaluation of risk factors for luxation after total hip replacement in dogs.Vet Surg. 2000 Nov-Dec;29(6):524-32. doi: 10.1053/jvet.2000.17858. Vet Surg. 2000. PMID: 11098785
-
Definition and determination of acetabular component orientation in cemented total hip arthroplasty.Vet Surg. 2000 Nov-Dec;29(6):507-16. doi: 10.1053/jvet.2000.17855. Vet Surg. 2000. PMID: 11098783
-
Management of total hip replacement luxation with triple pelvic osteotomy.Vet Surg. 2018 Nov;47(8):993-1001. doi: 10.1111/vsu.12949. Epub 2018 Sep 28. Vet Surg. 2018. PMID: 30267415
-
Acetabular components in total hip arthroplasty: is there evidence that cementless fixation is better?J Bone Joint Surg Am. 2013 Jan 16;95(2):168-74. doi: 10.2106/JBJS.K.01652. J Bone Joint Surg Am. 2013. PMID: 23324965 Review.
-
Application of arthroplasty principles to canine cemented total hip replacement.Vet Surg. 2000 Nov-Dec;29(6):578-93. doi: 10.1053/jvet.2000.17861. Vet Surg. 2000. PMID: 11098792 Review. No abstract available.
Cited by
-
Biomechanical evaluation of the impact of collared cementless total hip arthroplasty stems on implant subsidence: a cadaveric study in German Shepherd.Iran J Vet Res. 2023;24(3):242-246. doi: 10.22099/IJVR.2023.47029.6770. Iran J Vet Res. 2023. PMID: 38269008 Free PMC article.
-
Femoral Stem Fracture and Successful Reimplantation Using Femoral Window Technique in Canine Cemented Total Hip Replacement: Case Report.Front Vet Sci. 2021 Oct 6;8:716297. doi: 10.3389/fvets.2021.716297. eCollection 2021. Front Vet Sci. 2021. PMID: 34692804 Free PMC article.
-
Evaluation of ranges of motion of a new constrained acetabular prosthesis for canine total hip replacement.Biomed Eng Online. 2013 Nov 10;12:116. doi: 10.1186/1475-925X-12-116. Biomed Eng Online. 2013. PMID: 24207109 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical