Breath-hold three-dimensional CT of the liver with multi-detector row helical CT

Radiology. 2001 Apr;219(1):75-9. doi: 10.1148/radiology.219.1.r01ap2475.

Abstract

Purpose: To compare image quality on transverse source images and coronal and sagittal reformations to determine the feasibility of using single-breath-hold three-dimensional liver computed tomography (CT) with multi-detector row helical CT in patients suspected of having hepatic metastases.

Materials and methods: Fifty-three patients underwent the protocol. Coronal and sagittal reformations were constructed. Images were reviewed for duration of scan acquisition and length and adequacy of z-axis coverage. Reformations were scored for visualization of portal and hepatic vein branches, liver edge sharpness, cardiac pulsation and respiratory motion artifacts, noise due to mottle, and overall impression.

Results: Mean z-axis coverage was 207 mm +/- 33 (SD) (range, 145-280 mm), with a mean acquisition time of 10.96 seconds +/- 1.78 (range, 7.73-14.93 seconds). In 44 (83%) patients, the entire liver was imaged on a single helical scan. Artifact from cardiac motion was not identified on the transverse source images in any patient but was identified on coronal images in eight (15%) and on sagittal images in seven (13%). Similarly, noise due to mottle was not identified on the transverse source images but was identified on coronal images in seven (13%) patients and on sagittal images in six (11%).

Conclusion: It is feasible to perform single-breath-hold three-dimensional liver CT with multi-detector row helical CT technology. Reformations provide a unique perspective with which to view the liver and may improve diagnostic capacity.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Feasibility Studies
  • Female
  • Humans
  • Imaging, Three-Dimensional*
  • Liver / diagnostic imaging*
  • Liver Neoplasms / diagnostic imaging
  • Liver Neoplasms / secondary*
  • Male
  • Middle Aged
  • Radiographic Image Enhancement*
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed*