Combined anteroposterior spinal fixation provides superior stabilisation to a single anterior or posterior procedure
- PMID: 11380141
- DOI: 10.1302/0301-620x.83b4.9072
Combined anteroposterior spinal fixation provides superior stabilisation to a single anterior or posterior procedure
Abstract
Fusion is the main goal in the surgical management of the injured and unstable spine. A wide variety of implants is available to enhance this. Our study was performed to evaluate the stabilising characteristics of several anterior, posterior and combined systems of fixation. Six thoracolumbar (T11 to L2) spines from 13-week-old calves were first tested intact. Then the vertebral body of T13 was removed and the defect replaced and supported by a wooden block to simulate bone grafting. Dorsal implants consisting of a Universal Spine System (USS) fracture system and an AO Fixateur interne (AOFI), and ventral implants comprising of a Kaneda Classic, a Kaneda SR, a prototype of the VentroFix single clamp/single rod construct (SC/SR) and the VentroFix single clamp/double rod construct (SC/DR) were first implanted individually to stabilise the removal of the vertebral body. Simulating the combined anteroposterior stabilisations, all ventral implants were combined with the AOFI. The range of motion (ROM) was measured under loads of up to 7.5 Nm. The load was applied in a custom-made spine tester in the three primary directions while measuring the intervertebral movements using a goniometric linkage system. The dorsal systems limited ROM in flexion below 0.9 degrees and in extension between 3.3 degrees and 3.6 degrees (median values). The improved Kaneda System SR yielded a mean ROM of 1.8 degrees in flexion and in extension. The median rotation found with the VentroFix (SC/DR) was 3.2 degrees for flexion and 2.8 degrees for extension. Reinforcement of the ventral constructs with a dorsal system reduced the ROM in flexion and extension in all cases to 0.4 degrees and lower. In rotation, the median ROM of the anterior systems ranged from 2.7 degrees to 5.1 degrees and for the posterior systems from 3.9 degrees to 5.7 degrees, while the combinations provided a ROM of 1.2 degrees to 1.9 degrees. In lateral bending, the posterior implants restricted movement to 1.1 degrees, whereas the anterior implants allowed up to 5.2 degrees. The combined systems provided the highest stability at less than 0.6 degrees. Our study revealed distinct differences between posterior and anterior approaches in all primary directions. Also, different stabilisation characteristics were found within the anterior and posterior groups. Combinations of these two approaches provided the highest stability in all directions.
Similar articles
-
Biomechanical evaluation of lateral lumbar interbody fusion with secondary augmentation.J Neurosurg Spine. 2016 Dec;25(6):720-726. doi: 10.3171/2016.4.SPINE151386. Epub 2016 Jul 8. J Neurosurg Spine. 2016. PMID: 27391398
-
Three-dimensional motion analysis with Synex. Comparative biomechanical test series with a new vertebral body replacement for the thoracolumbar spine.Eur Spine J. 2000 Dec;9(6):472-85. doi: 10.1007/s005860000185. Eur Spine J. 2000. PMID: 11189915 Free PMC article.
-
Two column lesions in the thoracolumbar junction: anterior, posterior or combined approach? A comparative biomechanical in vitro investigation.Eur Spine J. 2007 Jun;16(6):813-20. doi: 10.1007/s00586-006-0201-1. Epub 2006 Aug 30. Eur Spine J. 2007. PMID: 16944226 Free PMC article.
-
Biomechanical evaluation of anterior thoracolumbar spinal instrumentation.Spine (Phila Pa 1976). 1995 Sep 15;20(18):1979-83. doi: 10.1097/00007632-199509150-00003. Spine (Phila Pa 1976). 1995. PMID: 8578371
-
Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis.J Neurosurg Spine. 2015 Feb;22(2):151-61. doi: 10.3171/2014.10.SPINE13805. Epub 2014 Dec 5. J Neurosurg Spine. 2015. PMID: 25478824 Review.
Cited by
-
Radiological and mid- to long-term patient-reported outcome after stabilization of traumatic thoraco-lumbar spinal fractures using an expandable vertebral body replacement implant.BMC Musculoskelet Disord. 2021 Aug 30;22(1):744. doi: 10.1186/s12891-021-04585-y. BMC Musculoskelet Disord. 2021. PMID: 34461863 Free PMC article.
-
A Rare Case of Contiguous Three-level Lumbar Burst Fractures-treated with Combined Posterior Stabilization and Anterior Fusion.J Orthop Case Rep. 2021 Feb;11(2):71-75. doi: 10.13107/jocr.2021.v11.i02.2032. J Orthop Case Rep. 2021. PMID: 34141675 Free PMC article.
-
Thoracic Spinal Stability and Motion Behavior Are Affected by the Length of Posterior Instrumentation After Vertebral Body Replacement, but Not by the Surgical Approach Type: An in vitro Study With Entire Rib Cage Specimens.Front Bioeng Biotechnol. 2020 Jun 9;8:572. doi: 10.3389/fbioe.2020.00572. eCollection 2020. Front Bioeng Biotechnol. 2020. PMID: 32582680 Free PMC article.
-
Evaluation of Titanium Serum Levels in Patients After Spine Instrumentation: Comparison Between Posterolateral and 360º Spinal Fusion Surgery.Cureus. 2019 Aug 21;11(8):e5451. doi: 10.7759/cureus.5451. Cureus. 2019. PMID: 31511816 Free PMC article.
-
The Role of Combined Posterior and Anterolateral Retroperitoneal Approach in the Treatment of Posttraumatic Burst Lumbar Fractures.Asian J Neurosurg. 2019 Apr-Jun;14(2):467-472. doi: 10.4103/ajns.AJNS_262_18. Asian J Neurosurg. 2019. PMID: 31143263 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials