Two-photon microscopy in brain tissue: parameters influencing the imaging depth
- PMID: 11574117
- DOI: 10.1016/s0165-0270(01)00438-1
Two-photon microscopy in brain tissue: parameters influencing the imaging depth
Erratum in
- J Neurosci Methods 2001 Dec 15;112(2):205
Abstract
Light scattering by tissue limits the imaging depth of two-photon microscopy and its use for functional brain imaging in vivo. We investigate the influence of scattering on both fluorescence excitation and collection, and identify tissue and instrument parameters that limit the imaging depth in the brain. (i) In brain slices, we measured that the scattering length at lambda=800 nm is a factor 2 higher in juvenile cortical tissue (P14-P18) than in adult tissue (P90). (ii) In a detection geometry typical for in vivo imaging, we show that the collected fraction of fluorescence drops at large depths, and that it is proportional to the square of the effective angular acceptance of the detection optics. Matching the angular acceptance of the microscope to that of the objective lens can result in a gain of approximately 3 in collection efficiency at large depths (>500 microm). A low-magnification (20x), high-numerical aperture objective (0.95) further increases fluorescence collection by a factor of approximately 10 compared with a standard 60x-63x objective without compromising the resolution. This improvement should allow fluorescence measurements related to neuronal or vascular brain activity at >100 microm deeper than with standard objectives.
Similar articles
-
Maximizing fluorescence collection efficiency in multiphoton microscopy.Opt Express. 2011 Aug 1;19(16):15348-62. doi: 10.1364/OE.19.015348. Opt Express. 2011. PMID: 21934897 Free PMC article.
-
Monte Carlo simulation of 3D mapping of cardiac electrical activity with spinning slit confocal optics.Conf Proc IEEE Eng Med Biol Soc. 2006;2006:1093-7. doi: 10.1109/IEMBS.2006.259837. Conf Proc IEEE Eng Med Biol Soc. 2006. PMID: 17946022
-
Sources of widefield fluorescence from the brain.Elife. 2020 Nov 6;9:e59841. doi: 10.7554/eLife.59841. Elife. 2020. PMID: 33155981 Free PMC article.
-
Choosing objective lenses: the importance of numerical aperture and magnification in digital optical microscopy.Biol Bull. 1998 Aug;195(1):1-4. doi: 10.2307/1542768. Biol Bull. 1998. PMID: 9739546 Review.
-
STED microscopy for nanoscale imaging in living brain slices.Methods. 2015 Oct 15;88:57-66. doi: 10.1016/j.ymeth.2015.06.006. Epub 2015 Jun 9. Methods. 2015. PMID: 26070997 Review.
Cited by
-
Comparison of the penetration depth in mouse brain in vivo through 3PF imaging using AIE nanoparticle labeling and THG imaging within the 1700 nm window.Nanoscale Adv. 2023 Dec 6;6(2):511-515. doi: 10.1039/d3na00871a. eCollection 2024 Jan 16. Nanoscale Adv. 2023. PMID: 38235073 Free PMC article.
-
Two-photon calcium imaging of neuronal activity.Nat Rev Methods Primers. 2022;2(1):67. doi: 10.1038/s43586-022-00147-1. Epub 2022 Sep 1. Nat Rev Methods Primers. 2022. PMID: 38124998 Free PMC article.
-
Advances in cellular resolution microscopy for brain imaging in rats.Neurophotonics. 2023 Oct;10(4):044304. doi: 10.1117/1.NPh.10.4.044304. Epub 2023 Nov 30. Neurophotonics. 2023. PMID: 38076724 Free PMC article. Review.
-
Optical constraints on two-photon voltage imaging.bioRxiv [Preprint]. 2023 Nov 18:2023.11.18.567441. doi: 10.1101/2023.11.18.567441. bioRxiv. 2023. PMID: 38014011 Free PMC article. Preprint.
-
SNR enhanced high-speed two-photon microscopy using a pulse picker and time gating detection.Sci Rep. 2023 Aug 30;13(1):14244. doi: 10.1038/s41598-023-41270-7. Sci Rep. 2023. PMID: 37648768 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials