. 2002 Sep;40(5):542-5.
doi: 10.1007/BF02345452.

Sauer's non-linear voltage division

Affiliations

Sauer's non-linear voltage division

H P Schwan et al. Med Biol Eng Comput. 2002 Sep.

Abstract

The non-linearity of the electrode-tissue interface impedance gives rise to harmonics and thus degrades the accuracy of impedance measurements. Also, electrodes are often driven into the non-linear range of their polarisation impedance. This is particularly true in clinical applications. Techniques to correct for electrode effects are usually based on linear electrode impedance data. However, these data can be very different from the non-linear values needed. Non-linear electrode data suggested a model based on simple assumptions. It is useful in predicting the frequency dependence of non-linear effects from linear properties. Sauer's treatment is a first attempt to provide a more general and rigorous basis for modelling the non-linear state. The paper reports Sauer's treatment of the non-linear case and points out its limitations. The paper considers Sauer's treatment of a series arrangement of two impedances. The tissue impedance is represented by a linear voltage-current characteristic. The interface impedance is represented by a Volterra expansion. The response of this network to periodic signals is calculated up to the second-order term of the series expansion. The resultant, time-dependent current is found to contain a DC term (rectification), as well as frequency-dependent terms. Sauer's treatment assumes a voltage clamp across the impedances and neglects higher-order terms in the series expansion. As a consequence, it fails adequately to represent some experimentally observed phenomena. It is therefore suggested that Sauer's expressions for the voltage divider should be combined with the non-linear treatments previously published by the co-authors. Although Sauer's work on the non-linear voltage divider was originally applied to the study of the non-linear behaviour of the electrode-electrolyte interface and biological tissues, it is stressed, however, that the work is applicable to a wide range of research areas.

PubMed Disclaimer