Observations on the suitability of the aethalometer for vehicular and workplace monitoring

J Air Waste Manag Assoc. 2002 Nov;52(11):1258-62. doi: 10.1080/10473289.2002.10470865.

Abstract

A field study was undertaken to evaluate the suitability of the aethalometer, an instrument capable of performing near-real-time measurement of low-level (10-1,000 ng/m3) airborne combustion products, for vehicular and workplace monitoring. Several technical limitations were identified: (1) there was no ready means for external calibration of optical measurements; (2) airflow rates were unstable; (3) effective range of concentrations was limited; and (4) the aethalometer demonstrated sensitivity to movement and vibration. Unless addressed, these limitations will restrict future uses of the aethalometer for vehicular and workplace monitoring.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Air Pollutants / analysis*
  • Air Pollution, Indoor / analysis*
  • Calibration
  • Environmental Monitoring / instrumentation*
  • Sensitivity and Specificity
  • Vehicle Emissions / analysis*
  • Vibration
  • Workplace*

Substances

  • Air Pollutants
  • Vehicle Emissions