Inflammation at the insertion site is not predictive of catheter-related bloodstream infection with short-term, noncuffed central venous catheters
- PMID: 12483050
- DOI: 10.1097/00003246-200212000-00003
Inflammation at the insertion site is not predictive of catheter-related bloodstream infection with short-term, noncuffed central venous catheters
Abstract
Background: Noncuffed, percutaneously inserted central venous catheters (CVCs) are widely used and cause at least 250,000 bloodstream infections (BSIs) in U.S. hospitals each year. We report a prospective study to determine whether inflammation at the insertion site is predictive of CVC-related BSI.
Methods: Percutaneously inserted, noncuffed CVCs inserted into the subclavian, internal jugular, or femoral vein in two randomized trials during 1998-2000 were prospectively studied; most patients were in an intensive care unit. The condition of the insertion site was evaluated daily by research nurses, quantifying pain (0, 1), erythema (0-2), swelling (0, 1), and purulence (0, 1); the lowest possible overall inflammation score was 0 and the highest was 5. CVC-related BSI was confirmed in each case by demonstrating concordance between isolates from the catheter segment and from blood cultures by restriction-fragment DNA subtyping.
Results: Among 1,263 CVCs prospectively studied, 333 (26.3%) were colonized at removal; of these, 35 catheters (2.7%) caused BSIs (5.9 per 1000 CVC days). BSIs were caused by coagulase-negative staphylococci (n = 27), enterococci (n = 4), enteric Gram-negative bacilli (n = 3), or (n = 1). Most insertion sites showed little or no inflammation at the time of removal. There were no significant differences among mean scores for each inflammatory variable examined or overall score among colonized CVCs (0.1 +/- 0.1), catheters causing CVC-related BSI (0.2 +/- 0.4), and noncolonized CVCs (0.1 +/- 0.1). The sensitivity of local inflammation for diagnosis of CVC-related BSI was dismal (0-3%).
Conclusion: Local inflammation is uncommon with infected CVCs, probably because most catheter-associated infections are currently caused by coagulase-negative staphylococci, a pathogen that incites little local or systemic inflammation. Whereas overt inflammation of the insertion site should raise suspicion of CVC-related BSI caused by or Gram-negative bacilli, especially if the patient has fever or other signs of sepsis, in general, site appearance cannot be relied on to identify catheter colonization or CVC-related BSI.
Comment in
-
Molecular mechanisms of slime production: a transferable operon explains how a saprophyte finds a home.Crit Care Med. 2002 Dec;30(12):2776. doi: 10.1097/00003246-200212000-00027. Crit Care Med. 2002. PMID: 12483074 No abstract available.
Similar articles
-
The pathogenesis of catheter-related bloodstream infection with noncuffed short-term central venous catheters.Intensive Care Med. 2004 Jan;30(1):62-7. doi: 10.1007/s00134-003-2045-z. Epub 2003 Nov 26. Intensive Care Med. 2004. PMID: 14647886
-
[Assessment of diagnostic methods for the catheter-related bloodstream infections in intensive care units].Mikrobiyol Bul. 2011 Jan;45(1):75-85. Mikrobiyol Bul. 2011. PMID: 21341162 Turkish.
-
Risk of catheter-related bloodstream infection with peripherally inserted central venous catheters used in hospitalized patients.Chest. 2005 Aug;128(2):489-95. doi: 10.1378/chest.128.2.489. Chest. 2005. PMID: 16100130 Review.
-
Central venous catheter-related bloodstream infections: an analysis of incidence and risk factors in a cohort of 400 patients.Intensive Care Med. 1998 Oct;24(10):1034-9. doi: 10.1007/s001340050712. Intensive Care Med. 1998. PMID: 9840236
-
The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies.Mayo Clin Proc. 2006 Sep;81(9):1159-71. doi: 10.4065/81.9.1159. Mayo Clin Proc. 2006. PMID: 16970212 Review.
Cited by
-
Comparative Effectiveness of 2 Chlorhexidine Gluconate-Containing Dressings in Reducing Central Line-Associated Bloodstream Infections, Hospital Stay, and Costs.Inquiry. 2023 Jan-Dec;60:469580231214751. doi: 10.1177/00469580231214751. Inquiry. 2023. PMID: 38037829 Free PMC article.
-
Staphylococcus epidermidis biofilm assembly and self-dispersion: bacteria and matrix dynamics.Int Microbiol. 2024 Jun;27(3):831-844. doi: 10.1007/s10123-023-00433-2. Epub 2023 Oct 12. Int Microbiol. 2024. PMID: 37824024
-
Two cases of bloodstream infections associated with opportunistic bacterial species (Enterococcus hirae and Enterobacter xiangfangensis) in companion animals.BMC Vet Res. 2023 Mar 25;19(1):63. doi: 10.1186/s12917-023-03615-2. BMC Vet Res. 2023. PMID: 36966282 Free PMC article.
-
Measurement of Plasma Galectin-3 Concentrations in Patients with Catheter Infections: A Post Hoc Retrospective Cohort Study.Diagnostics (Basel). 2022 Oct 6;12(10):2418. doi: 10.3390/diagnostics12102418. Diagnostics (Basel). 2022. PMID: 36292107 Free PMC article.
-
Development and validation of a multivariable prediction model of central venous catheter-tip colonization in a cohort of five randomized trials.Crit Care. 2022 Jul 7;26(1):205. doi: 10.1186/s13054-022-04078-x. Crit Care. 2022. PMID: 35799302 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical