Mandibular flexure and stress build-up in mandibular full-arch fixed prostheses supported by osseointegrated implants
- PMID: 12562372
- DOI: 10.1034/j.1600-0501.2003.140114.x
Mandibular flexure and stress build-up in mandibular full-arch fixed prostheses supported by osseointegrated implants
Abstract
The biomechanical effect of mandibular functional flexure on stress build-up in implant-supported fixed restorations is discussed. The relative deformations and stress distributions in six different designs of implant-supported prosthetic systems (six or four implants, with or without distal cantilevers, cross-arch or midline-divided bar into two free-standing bridges) were analysed by a three-dimensional finite element (FE) model of a human edentulous mandible. A significant amount of stress in the more distal implants and the superstructure at the symphysis arises as a consequence of mandible functional flexure. The analysis of the stress distributions generated by the different restorative patterns suggests that a division of the superstructure at the level of the symphysis significantly restores the natural functional flexure of the mandible.
Similar articles
-
Three-dimensional finite element analysis of the effect of 1-piece superstructure on mandibular flexure.Implant Dent. 2009 Oct;18(5):428-37. doi: 10.1097/ID.0b013e3181ad8d87. Implant Dent. 2009. PMID: 22129961
-
Stress Distribution Study Using the Finite Element Method in Three Different Implant-Supported Fixed Complete-Arch Mandibular Prostheses.Int J Prosthodont. 2016 May-Jun;29(3):299-302. doi: 10.11607/ijp.4427. Int J Prosthodont. 2016. PMID: 27148996
-
Influence of implant framework and mandibular flexure on the strain distribution on a Kennedy class II mandible restored with a long-span implant fixed restoration: a pilot study.J Prosthet Dent. 2014 Jul;112(1):31-7. doi: 10.1016/j.prosdent.2013.08.012. Epub 2014 Jan 3. J Prosthet Dent. 2014. PMID: 24388719
-
Mandibular flexure and its significance on implant fixed prostheses: a review.J Prosthodont. 2012 Apr;21(3):219-24. doi: 10.1111/j.1532-849X.2011.00798.x. Epub 2011 Nov 1. J Prosthodont. 2012. PMID: 22044758 Review.
-
The implant-supported prosthesis for the edentulous arch: design considerations.J Prosthet Dent. 1997 Jul;78(1):28-33. doi: 10.1016/s0022-3913(97)70084-2. J Prosthet Dent. 1997. PMID: 9237143 Review.
Cited by
-
Maxillary Cast Partial Denture and Mandibular Implant-Supported Metal-Ceramic Prosthesis With a Split Framework to Compensate for Mandibular Flexure: A Case Report.Cureus. 2023 Nov 19;15(11):e49071. doi: 10.7759/cureus.49071. eCollection 2023 Nov. Cureus. 2023. PMID: 38130512 Free PMC article.
-
Median mandibular flexure-the unique physiological phenomenon of the mandible and its clinical significance in implant restoration.Front Bioeng Biotechnol. 2023 Sep 7;11:1238181. doi: 10.3389/fbioe.2023.1238181. eCollection 2023. Front Bioeng Biotechnol. 2023. PMID: 37744259 Free PMC article. Review.
-
Retrospective digital study of mandibular flexure in patients with long-span fixed restorations supported by natural teeth.BMC Res Notes. 2023 Sep 11;16(1):203. doi: 10.1186/s13104-023-06486-w. BMC Res Notes. 2023. PMID: 37697386 Free PMC article.
-
Biomechanical Implications of Mandibular Flexion on Implant-Supported Full-Arch Rehabilitations: A Systematic Literature Review.J Clin Med. 2023 Aug 15;12(16):5302. doi: 10.3390/jcm12165302. J Clin Med. 2023. PMID: 37629344 Free PMC article. Review.
-
Influence of implants number on the biomechanical behavior of implant-supported complete prosthesis: A 3D finite element analysis.Heliyon. 2023 Jul 8;9(7):e17956. doi: 10.1016/j.heliyon.2023.e17956. eCollection 2023 Jul. Heliyon. 2023. PMID: 37483728 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
