Comparison of ethanol concentrations in venous blood and end-expired breath during a controlled drinking study

Forensic Sci Int. 2003 Mar 12;132(1):18-25. doi: 10.1016/s0379-0738(02)00417-6.

Abstract

Concentration-time profiles of ethanol were determined for venous whole blood and end-expired breath during a controlled drinking experiment in which healthy men (n=9) and women (n=9) drank 0.40-0.65 g ethanol per kg body weight in 20-30 min. Specimens of blood and breath were obtained for analysis of ethanol starting at 50-60 min post-dosing and then every 30-60 min for 3-6 h. This protocol furnished 130 blood-breath pairs for statistical evaluation. Blood-ethanol concentration (BAC, mg/g) was determined by headspace gas chromatography and breath-ethanol concentration (BrAC, mg/2l) was determined with a quantitative infrared analyzer (Intoxilyzer 5000S), which is the instrument currently used in Sweden for legal purposes. In 18 instances the Intoxilyzer 5000S gave readings of 0.00 mg/2l whereas the actual BAC was 0.08 mg/g on average (range 0.04-0.15 mg/g). The remaining 112 blood- and breath-alcohol measurements were highly correlated (r=0.97) and the regression relationship was BAC=0.10+0.91BrAC and the residual standard deviation (S.D.) was 0.042 mg/g (8.4%). The slope (0.91+/-0.0217) differed significantly from unity being 9% low and the intercept (0.10+/-0.0101) deviated from zero (t=10.2, P<0.001), indicating the presence of both proportional and constant bias, respectively. The mean bias (BAC - BrAC) was 0.068 mg/g and the 95% limits of agreement were -0.021 and 0.156 mg/g. The average BAC/BrAC ratio was 2448+/-540 (+/-S.D.) with a median of 2351 and 2.5th and 97.5th percentiles of 1836 and 4082. We found no significant gender-related differences in BAC/BrAC ratios, being 2553+/-576 for men and 2417+/-494 for women (t=1.34, P>0.05). The mean rate of ethanol disappearance from blood was 0.157+/-0.021 mg/(g per hour), which was very close to the elimination rate from breath of 0.161+/-0.021 mg/(2l per hour) (P>0.05). Breath-test results obtained with Intoxilyzer 5000S (mg/2l) were generally less than the coexisting concentrations of ethanol in venous blood (mg/g), which gives an advantage to the suspect who provides breath compared with blood in cases close to a threshold alcohol limit.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Alcoholic Intoxication / blood
  • Alcoholic Intoxication / diagnosis*
  • Breath Tests / instrumentation*
  • Chromatography, Gas
  • Data Interpretation, Statistical
  • Ethanol / blood*
  • Ethanol / pharmacokinetics*
  • Female
  • Forensic Medicine / instrumentation
  • Forensic Medicine / methods
  • Humans
  • Linear Models
  • Male
  • Regression Analysis
  • Time Factors

Substances

  • Ethanol