Arm position and blood pressure: a risk factor for hypertension?

J Hum Hypertens. 2003 Jun;17(6):389-95. doi: 10.1038/sj.jhh.1001563.

Abstract

The objective of this study was to re-evaluate the effect of arm position on blood pressure (BP) measurement with auscultatory and oscillometric methods including ambulatory blood pressure monitoring (ABPM). The setting was the hospital outpatient department and the subjects chosen were normotensive and hypertensive. The effect of lowering the arm from heart level on indirect systolic BP (SBP) and diastolic BP (DBP) measurement as well as the importance of supporting the horizontal arm were measured. In the sitting position, lowering the supported horizontal arm to the dependent position increased BP measured by a mercury device from 103+/-10/60+/-7 to 111+/-14/67+/-10 mmHg in normotensive subjects, a mean increase of 8/7 mmHg (P<0.01). In hypertensive subjects, a similar manoeuvre increased BP from 143+/-21/78+/-17 to 166+/-29/88+/-20 mmHg, an increase of 23/10 mmHg (P<0.01). Combined results from normotensive and hypertensive subjects demonstrate a direct and proportional association between BP (SBP and DBP) and the increase produced by arm dependency. Similar changes and associations were noted with oscillometric devices in the clinic situation. However, supporting the horizontal arm did not alter BP. Of particular interest, analysis of 13 hypertensive subjects who underwent ABPM on two occasions, once with the arm in the 'usual' position and once with the arm held horizontally for BP measurement during waking hours, demonstrated changes comparable to the other devices. The mean 12-hour BP was 154+/-19/82+/-10 mmHg during the former period and significantly decreased to 141+/-18/74+/-9 mmHg during the latter period (P<0.01). Regression analysis of the change in SBP and DBP with arm position change again demonstrated a close correlation (r(2)=0.8113 and 0.7273; P<0.001) with the artefact being larger with higher systolic and diastolic pressures. In conclusion, arm movements lead to significant artefacts in BP measurement, which are greater, the higher the systolic or diastolic pressure. These systematic errors occur when using both auscultatory and oscillometric (clinic and ABPM) devices and might lead to an erroneous diagnosis of hypertension and unnecessary medication, particularly in individuals with high normal BP levels. Since clinical interpretations of heart level vary, the horizontal arm position should be the unambiguous standard for all sitting and standing BP auscultatory and oscillometric measurements.

Publication types

  • Evaluation Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Arm / physiopathology*
  • Blood Pressure / physiology*
  • Blood Pressure Determination
  • Circadian Rhythm / physiology
  • Diagnostic Errors*
  • Female
  • Humans
  • Hypertension / diagnosis
  • Hypertension / etiology*
  • Hypertension / physiopathology*
  • Male
  • Middle Aged
  • Posture / physiology*
  • Reproducibility of Results
  • Risk Factors