Legionella species isolated from cooling towers in Kuala Lumpur

Med J Malaysia. 1992 Mar;47(1):15-9.

Abstract

Three building complexes in Kuala Lumpur were surveyed for the presence of legionellae in cooling towers. The organisms were grown from 12 out of 46 samples of water collected from 30 towers. L. pneumophila serogroups 1 and 7 were the commonest serogroups isolated. None belonged to the Pontiac subgroup of L. pneumophila serogroup 1.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Legionella / isolation & purification*
  • Malaysia
  • Water Microbiology*