Cantilever rests: an alternative to the unsupported distal cantilever of osseointegrated implant-supported prostheses for the edentulous mandible
- PMID: 1432807
- DOI: 10.1016/0022-3913(92)90209-s
Cantilever rests: an alternative to the unsupported distal cantilever of osseointegrated implant-supported prostheses for the edentulous mandible
Abstract
Mandibular prostheses supported by implants placed between the mandibular foramina restrict the length of the distally cantilevered components to minimize torque-related stress to the supporting implants. Additional posterior implants used as abutments with rigid attachments better distribute occlusal forces and reduce cantilever torque to the anterior implants. Because of the phenomenon of mandibular flexure, these posterior implants could be subjected to stress-induced microdamage to the bone-implant interface. The use of posterior abutments for support of the cantilever without connection reduces the potential hazard of stress-induced microdamage.
Similar articles
-
Retrospective analysis of bar-retained dentures with cantilever extension: marginal bone level changes around dental implants over time.Int J Oral Maxillofac Implants. 2010 Mar-Apr;25(2):385-93. Int J Oral Maxillofac Implants. 2010. PMID: 20369100
-
Evaluation of stress patterns produced by implant-retained overdentures and implant-retained fixed partial denture.J Craniofac Surg. 2011 Nov;22(6):2153-7. doi: 10.1097/SCS.0b013e3182323e29. J Craniofac Surg. 2011. PMID: 22067869
-
On occlusal forces in dentitions with implant-supported fixed cantilever prostheses.Swed Dent J Suppl. 1990;69:1-40. Swed Dent J Suppl. 1990. PMID: 2196708
-
Cantilever and implant biomechanics: a review of the literature. Part 1.J Prosthodont. 1994 Mar;3(1):41-6. doi: 10.1111/j.1532-849x.1994.tb00124.x. J Prosthodont. 1994. PMID: 8061790 Review.
-
The cantilever fixed partial denture--a literature review.J Prosthet Dent. 1992 Apr;67(4):484-7. doi: 10.1016/0022-3913(92)90077-n. J Prosthet Dent. 1992. PMID: 1507130 Review.
Cited by
-
Biomechanical Implications of Mandibular Flexion on Implant-Supported Full-Arch Rehabilitations: A Systematic Literature Review.J Clin Med. 2023 Aug 15;12(16):5302. doi: 10.3390/jcm12165302. J Clin Med. 2023. PMID: 37629344 Free PMC article. Review.
-
The effect of mandibular flexure on the design of implant-supported fixed restorations of different facial types under two loading conditions by three-dimensional finite element analysis.Front Bioeng Biotechnol. 2022 Aug 29;10:928656. doi: 10.3389/fbioe.2022.928656. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 36105608 Free PMC article.
-
Effect of cantilever length on stress distribution around implants in mandibular overdentures supported by two and three implants.Eur J Dent. 2016 Jul-Sep;10(3):333-340. doi: 10.4103/1305-7456.184152. Eur J Dent. 2016. PMID: 27403049 Free PMC article.
-
Split-Framework in Mandibular Implant-Supported Prosthesis.Case Rep Dent. 2015;2015:502394. doi: 10.1155/2015/502394. Epub 2015 Dec 3. Case Rep Dent. 2015. PMID: 26770841 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources