Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature
- PMID: 14552579
- DOI: 10.1109/TMI.2003.817791
Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature
Abstract
Using three-dimensional rotational X-ray angiography (3DRA), three-dimensional (3-D) information of the vasculature can be obtained prior to endovascular interventions. However, during interventions, the radiologist has to rely on fluoroscopy images to manipulate the guide wire. In order to take full advantage of the 3-D information from 3DRA data during endovascular interventions, a method is presented that yields an integrated display of the position of the guide wire and vasculature in 3-D. The method relies on an automated method that tracks the guide wire simultaneously in biplane fluoroscopy images. Based on the calibrated geometry of the C-arm, the 3-D guide-wire position is determined and visualized in the 3-D coordinate system of the vasculature. The method is evaluated in an intracranial anthropomorphic vascular phantom. The influence of the angle between projections, distortion correction of the projection images, and accuracy of geometry knowledge on the accuracy of 3-D guide-wire reconstruction from biplane images is determined. If the calibrated geometry information is used and the images are corrected for distortion, a mean distance to the reference standard of 0.42 mm and a tip distance of 0.65 mm is found, which means that accurate guide-wire reconstruction from biplane images can be performed.
Similar articles
-
Guide wire reconstruction and visualization in 3DRA using monoplane fluoroscopic imaging.IEEE Trans Med Imaging. 2005 May;24(5):612-23. doi: 10.1109/TMI.2005.844073. IEEE Trans Med Imaging. 2005. PMID: 15889549
-
Guide-wire tracking during endovascular interventions.IEEE Trans Med Imaging. 2003 Aug;22(8):965-72. doi: 10.1109/TMI.2003.815904. IEEE Trans Med Imaging. 2003. PMID: 12906251
-
Temporal estimation of the 3d guide-wire position using 2d X-ray images.Med Image Comput Comput Assist Interv. 2009;12(Pt 1):386-93. Med Image Comput Comput Assist Interv. 2009. PMID: 20426011
-
Electromagnetic navigation with multimodality image fusion for image-guided percutaneous interventions.Tech Vasc Interv Radiol. 2013 Sep;16(3):177-81. doi: 10.1053/j.tvir.2013.02.013. Tech Vasc Interv Radiol. 2013. PMID: 23993080 Review.
-
Functional angiography.Crit Rev Biomed Eng. 2005;33(1):1-102. doi: 10.1615/critrevbiomedeng.v33.i1.10. Crit Rev Biomed Eng. 2005. PMID: 15777157 Review.
Cited by
-
3D localization from 2D X-ray projection.Int J Comput Assist Radiol Surg. 2022 Sep;17(9):1553-1558. doi: 10.1007/s11548-022-02709-w. Epub 2022 Jul 11. Int J Comput Assist Radiol Surg. 2022. PMID: 35819654 Free PMC article.
-
Shape Reconstruction Processes for Interventional Application Devices: State of the Art, Progress, and Future Directions.Front Robot AI. 2021 Nov 19;8:758411. doi: 10.3389/frobt.2021.758411. eCollection 2021. Front Robot AI. 2021. PMID: 34869615 Free PMC article. Review.
-
Simultaneous reconstruction of multiple stiff wires from a single X-ray projection for endovascular aortic repair.Int J Comput Assist Radiol Surg. 2019 Nov;14(11):1891-1899. doi: 10.1007/s11548-019-02052-7. Epub 2019 Aug 22. Int J Comput Assist Radiol Surg. 2019. PMID: 31440962
-
A dynamic model-based approach to motion and deformation tracking of prosthetic valves from biplane x-ray images.Med Phys. 2018 Jun;45(6):2583-2594. doi: 10.1002/mp.12913. Epub 2018 May 3. Med Phys. 2018. PMID: 29659023 Free PMC article.
-
4D interventional device reconstruction from biplane fluoroscopy.Med Phys. 2016 Mar;43(3):1324-34. doi: 10.1118/1.4941950. Med Phys. 2016. PMID: 26936717 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources