The multifocal pattern electroretinogram in glaucoma

Vision Res. 2004 Jan;44(1):103-12. doi: 10.1016/j.visres.2003.08.012.

Abstract

Background: The pattern ERG can be used to detect early glaucomatous change, because the response of cells in the inner retina from (typically) 20 degrees -40 degrees of area is reduced before perimetric abnormality is certain. The multifocal pattern electroretinogram (mfPERG) allows analysis of many local regions within this area. The aim of this study was to investigate whether in patients with presumed glaucoma the mfPERG permits diagnosis and discrimination from normals.

Methods: Measurements on 25 age-related normal eyes were compared to those on 23 eyes with different stages of glaucoma. A RETIScan system was used to generate a stimulus pattern of 19 hexagons, each consisting of six triangles. The triangles pattern-reversed black to white at 75 Hz. Those 19 hexagons were grouped into three stimulus regions: a central field, a middle, and a peripheral ring. The complete array subtended 48 degrees at the eye. The hexagons alternated between black and white, in a temporal pattern that followed a corrected binary m-sequence (length 512, 10 cycles with 39 s each). The amplitudes and latencies of positive responses at approximately 50 ms (P-50) and negative responses at approximately 95 ms (N-95) were analyzed.

Results: In patients with glaucoma the P-50 and N-95 components of the mfPERG were significantly reduced for the central area and both outer rings compared to normal volunteers (p<0.001, Mann-Whitney-U). The most distinct reduction was observed for N-95 and the central ring. Changes in latencies were not conclusive. The reduction of the components increased with the stage of glaucoma. A predictive model for detecting early glaucomatous changes was designed based on P-50-N-95 with 88% sensitivity and 76% specificity.

Conclusion: In glaucoma a marked reduction of components, especially centrally is observed in the mfPERG. This hints to an early involvement of central ganglion cells and may be useful for future functional tests.

MeSH terms

  • Adult
  • Aged
  • Electroretinography / methods*
  • Female
  • Glaucoma / diagnosis*
  • Glaucoma / physiopathology
  • Humans
  • Male
  • Middle Aged
  • Pattern Recognition, Visual / physiology
  • Predictive Value of Tests
  • Retinal Ganglion Cells / physiology
  • Sensitivity and Specificity
  • Visual Acuity / physiology