Analysis of force profile during a maximum voluntary isometric contraction task

Muscle Nerve. 2004 Mar;29(3):401-8. doi: 10.1002/mus.10564.

Abstract

This study analyses maximum voluntary isometric contraction (MVIC) and its measurement by recording the force profile during maximal-effort, 7-s hand-grip contractions. Six healthy subjects each performed three trials repeated at short intervals to study variation from fatigue. These three trials were performed during three separate sessions at daily intervals to look at random variation. A pattern of force development during a trial was identified. An initiation phase, with or without an initiation peak, was followed by a maintenance phase, sometimes with secondary pulses and an underlying decline in force. Of these three MVIC parameters, maximum force during the maintenance phase showed less random variability compared to intertrial fatigue variability than did maximum force during the initiation phase or absolute maximum force. Analysis of MVIC as a task, rather than a single, maximal value reveals deeper levels of motor control in its generation. Thus, force parameters other than the absolute maximum force may be better suited to quantification of muscle performance in health and disease.

MeSH terms

  • Adult
  • Artifacts
  • Hand Strength / physiology
  • Humans
  • Isometric Contraction / physiology*
  • Male
  • Middle Aged
  • Muscle Fatigue / physiology
  • Muscle, Skeletal / innervation
  • Muscle, Skeletal / physiology*
  • Reaction Time / physiology
  • Stress, Mechanical
  • Volition / physiology