Variation in prostate specific antigen results from 2 different assay platforms: clinical impact on 2304 patients undergoing prostate cancer screening
- PMID: 15126793
- DOI: 10.1097/01.ju.0000127736.86597.e7
Variation in prostate specific antigen results from 2 different assay platforms: clinical impact on 2304 patients undergoing prostate cancer screening
Abstract
Purpose: Urologists must contend with fluctuating prostate specific antigen (PSA) results from different assay platforms when deciding whether prostate biopsy is indicated. The contribution of cross-platform variation to these fluctuations is not well understood. To address this question we performed a cross-sectional study comparing 2 popular PSA assays during prostate cancer screening.
Materials and methods: The Baylor College of Medicine Prostate Cancer Screening Program is a community outreach program providing free screening to Houston residents. From September 18th to 23, 2000, 2,304 patients underwent digital rectal examination and parallel serum PSA assay by the Hybritech Access (Beckman Coulter, Inc., Chaska, Minnesota) and Centaur (Bayer Diagnostics, Tarrytown, New York) systems. The Wilcoxon signed ranks test was used to compare results.
Results: Median PSA was low for the 2 assays (Centaur 0.99 ng/ml and Access 1.09 ng/ml) and Access results were significantly higher (1.23 times) than those obtained with Centaur (p <0.001). Frozen serum from 50 patients with PSA greater than 2.5 were then re-assayed using a third methodology (third Generation Immulite, Diagnostic Products Corp., Los Angeles, California). These data were consistent with Centaur results and significantly lower than Access results (p <0.001). Using a cutoff of PSA greater than 4.0 ng/ml 55 of the 288 patients (19%) with PSA greater than 2.5 ng/ml on the 2 platforms would have been candidates for prostate biopsy based on Access but not on Centaur data.
Conclusions: In a large screening population the Access system measured consistently higher PSA than the Centaur system. These findings provide a basis for interpreting PSA results obtained from 2 commonly used clinical assays.
Similar articles
-
Prostate cancer screening within a prostate specific antigen range of 3 to 3.9 ng./ml.: a comparison of digital rectal examination and free prostate specific antigen as supplemental screening tests.J Urol. 2001 Oct;166(4):1339-42. J Urol. 2001. PMID: 11547069
-
Comparative analysis of complexed prostate specific antigen, free prostate specific antigen and their ratio in detecting prostate cancer.J Urol. 2002 May;167(5):2017-23; discussion 2023-4. doi: 10.1016/s0022-5347(05)65075-6. J Urol. 2002. PMID: 11956430
-
Prostate specific antigen assay standardization bias could affect clinical decision making.J Urol. 2008 Nov;180(5):1959-62; discussion 1962-3. doi: 10.1016/j.juro.2008.07.036. Epub 2008 Sep 17. J Urol. 2008. PMID: 18801532
-
Significance of serum free prostate specific antigen in the screening of prostate cancer.J Urol. 1996 Dec;156(6):1964-8. J Urol. 1996. PMID: 8911366 Review.
-
Prostate-specific antigen and the early diagnosis of prostate cancer.Am J Clin Pathol. 2002 Jun;117 Suppl:S104-8. doi: 10.1309/C4UN-12LK-43HP-JXY3. Am J Clin Pathol. 2002. PMID: 14569806 Review.
Cited by
-
Novel Metabolic Signatures of Prostate Cancer Revealed by 1H-NMR Metabolomics of Urine.Diagnostics (Basel). 2021 Jan 20;11(2):149. doi: 10.3390/diagnostics11020149. Diagnostics (Basel). 2021. PMID: 33498542 Free PMC article.
-
Prostate hyperplasia in St Mary's Hospital Lacor: utility of prostate specific antigen in screening for prostate malignancy.Afr Health Sci. 2020 Sep;20(3):1259-1263. doi: 10.4314/ahs.v20i3.30. Afr Health Sci. 2020. PMID: 33402973 Free PMC article.
-
Explication of the roles of prostate health index (PHI) and urokinase plasminogen activator (uPA) as diagnostic and predictor tools for prostate cancer in equivocal PSA range of 4-10 ng/mL.Saudi J Biol Sci. 2020 Aug;27(8):1975-1984. doi: 10.1016/j.sjbs.2020.04.004. Epub 2020 Apr 10. Saudi J Biol Sci. 2020. PMID: 32714021 Free PMC article.
-
Specific expression pattern of tissue cytokines analyzed through the Surface Acoustic Wave technique is associated with age-related spontaneous benign prostatic hyperplasia in rats.Biochem Biophys Rep. 2018 Apr 2;14:26-34. doi: 10.1016/j.bbrep.2018.03.005. eCollection 2018 Jul. Biochem Biophys Rep. 2018. PMID: 29872731 Free PMC article.
-
GC-MS-Based Endometabolome Analysis Differentiates Prostate Cancer from Normal Prostate Cells.Metabolites. 2018 Mar 19;8(1):23. doi: 10.3390/metabo8010023. Metabolites. 2018. PMID: 29562689 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous