D-dimer testing for deep venous thrombosis: a metaanalysis

Clin Chem. 2004 Jul;50(7):1136-47. doi: 10.1373/clinchem.2004.031765. Epub 2004 May 13.

Abstract

Background: The use of D-dimer assays as a rule-out test for deep venous thrombosis (DVT) is controversial. To clarify this issue we performed a systematic review of the relevant literature.

Methods: We identified eligible studies, using MEDLINE entries from February 1995 through October 2003, supplemented by a review of bibliographies of relevant articles. Studies reporting accuracy evaluations comparing D-dimer test results with lower extremity ultrasound or venography in symptomatic patients with suspected acute DVT were selected for review. Two reviewers critically appraised each study independently according to previously established methodologic standards for diagnostic test research. Those studies judged to be of highest quality were designated Level 1.

Results: The 23 Level 1 studies reported data on 21 different D-dimer assays. There was wide variation in assay sensitivity, specificity, and negative predictive values, and major differences in methodology of reviewed studies. A multivariate analysis of assay performance, controlling for sample size, DVT prevalence, reference standard, and patient mix, found few differences among the assays in effect on test performance as measured by diagnostic odds ratio. Increasing prevalence of DVT was associated with poorer test performance (P = 0.01), whereas the choice of venography as the reference standard was associated with better test performance (P <0.005).

Conclusions: Explanations for the wide variation in assay performance include differences in biochemical and technical characteristics of the assays, heterogeneity and small size of patient groups, and bias introduced by choice of reference standards. Assay sensitivity and negative predictive value were frequently <90%, uncharacteristic of a good rule-out test. General use of D-dimer assays as a stand-alone test for the diagnosis of DVT is not supported by the literature.

Publication types

  • Meta-Analysis
  • Research Support, U.S. Gov't, P.H.S.
  • Systematic Review

MeSH terms

  • Biomarkers / blood
  • Fibrin Fibrinogen Degradation Products / analysis*
  • Fibrin Fibrinogen Degradation Products / standards
  • Humans
  • Predictive Value of Tests
  • Reference Standards
  • Sensitivity and Specificity
  • Venous Thrombosis / blood
  • Venous Thrombosis / diagnosis*

Substances

  • Biomarkers
  • Fibrin Fibrinogen Degradation Products
  • fibrin fragment D