Effect of anterior capsule polishing on fibrotic capsule opacification: three-year results

J Cataract Refract Surg. 2004 Nov;30(11):2322-7. doi: 10.1016/j.jcrs.2004.02.092.

Abstract

Purpose: To evaluate the long-term effect of anterior capsule polishing on anterior capsule opacification (ACO) and peripheral fibrotic posterior capsule opacification (PCO).

Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.

Methods: This randomized double-blind study comprised 104 eyes of 52 patients with bilateral age-related cataract. All patients received round-edged intraocular lenses (IOLs); 26 received an SI-40 IOL (Advanced Medical Optics Inc.) in both eyes, and 26 received a Silens6 IOL (Domilens) in both eyes. Both IOLs consist of different silicone material and have different haptic angulation. The SI-40 IOL has 13.0 mm open-loop poly(methyl methacrylate) (PMMA) haptics angulated by 10 degrees. The Silens6 IOL has 12.5 mm open-loop PMMA haptics with no angulation. In 1 eye, the anterior capsule was extensively polished. The anterior capsule was left unpolished in the contralateral eye, which acted as a control. Digital slitlamp photographs of the ACO and fibrotic PCO were taken with a standardized technique for 3 years postoperatively. The intensity of ACO was measured objectively (score 0% to 100%) using Adobe Photoshop software. Fibrotic PCO was graded subjectively (score 0 to 4).

Results: The mean ACO was 17% in the polished eyes and 26% in the control eyes (P = .0001). The mean fibrotic PCO score was 0.5 and 1.0, respectively (P = .0007). The mean ACO was 15% in the polished SI-40 eyes and 26% in the control SI-40 eyes (P = .01). It was 19% in the polished Silens6 eyes and 26% in the control Silens6 eyes (P = .003). The mean fibrotic PCO score was 0.4 in the polished SI-40 eyes and 1.1 in the control SI-40 eyes (P = .0006). It was 0.6 in the polished Silens6 eyes and 0.9 in the control Silens6 eyes (P = .08).

Conclusions: Three years after surgery, eyes in which the anterior capsule was extensively polished had less ACO and fibrotic PCO with both round-edged silicone IOLs. In eyes with Silens6 IOLs, however, the reduction in fibrotic PCO was not significant.

Publication types

  • Clinical Trial
  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Capsulorhexis
  • Cataract / etiology*
  • Double-Blind Method
  • Epithelial Cells / pathology
  • Fibrosis
  • Follow-Up Studies
  • Humans
  • Incidence
  • Lens Capsule, Crystalline / pathology*
  • Lens Capsule, Crystalline / surgery*
  • Lens Implantation, Intraocular
  • Lenses, Intraocular
  • Phacoemulsification
  • Prospective Studies
  • Prosthesis Design
  • Silicone Elastomers
  • Suction / methods*

Substances

  • Silicone Elastomers