Considering risks to healthcare workers from glutaraldehyde alternatives in high-level disinfection
- PMID: 15571847
- DOI: 10.1016/j.jhin.2004.07.003
Considering risks to healthcare workers from glutaraldehyde alternatives in high-level disinfection
Abstract
Due to concerns over glutaraldehyde's toxicity, two substitutes have recently been introduced; ortho-phthalaldehyde (OPA), and a mixture of hydrogen peroxide and peracetic acid. There is limited information about the health effects for employees from these products. This study assesses the current practices regarding the use of high-level disinfectants in British Columbian hospitals and predicts the relative toxicities of each product. Industry practices were compiled using a comprehensive survey of current practices and decision processes in all hospitals in British Columbia. Of 95 hospitals, 64 returned surveys; 80% of these used high-level disinfection. Among user hospitals, 49% used glutaraldehyde alone and 51% had introduced alternatives. Concern about staff health was the most common reason for substituting, but this was frequently not considered when choosing specific alternatives. Hospitals that involved occupational health, infection control or regional staff in high-level disinfectant decisions used glutaraldehyde alternatives less often. In most hospitals, it was difficult to find individuals who were knowledgeable about the use of disinfectants. Potential health effects associated with each type of high-level disinfectant were assessed by review of the published literature and available manufacturers' data along with qualitative structure-activity relationship analysis. Results indicated that although all products irritate the skin and respiratory tract, OPA is a potential dermal and respiratory sensitizer but hydrogen peroxide and peracetic acid do not cause allergic reactions. Despite little being known about the risks to employees from glutaraldehyde alternatives, their use is widespread. The potential risks of all high-level disinfectants are serious; thus regulators and users are faced with important risk management decisions before and after they have been introduced into the workplace.
Similar articles
-
Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee.Gut. 1998 Apr;42(4):585-93. Gut. 1998. PMID: 9616326 Free PMC article.
-
Evaluation of occupational exposure to high-level disinfectants in endoscopic services in an Italian hospital.Int J Immunopathol Pharmacol. 2006 Oct-Dec;19(4 Suppl):73-7. Int J Immunopathol Pharmacol. 2006. PMID: 17291411
-
Evidence-based decision making in an endoscopy nurse with respiratory symptoms exposed to the new ortho-phthalaldehyde (OPA) disinfectant.Occup Med (Lond). 2005 Oct;55(7):575-8. doi: 10.1093/occmed/kqi119. Occup Med (Lond). 2005. PMID: 16251378 Review.
-
A new peroxide-based flexible endoscope-compatible high-level disinfectant.Am J Infect Control. 2006 Nov;34(9):571-7. doi: 10.1016/j.ajic.2006.02.003. Am J Infect Control. 2006. PMID: 17097451
-
Allergy to ortho-phthalaldehyde in the healthcare setting: advice for clinicians.Expert Rev Clin Immunol. 2013 Mar;9(3):227-34. doi: 10.1586/eci.12.107. Expert Rev Clin Immunol. 2013. PMID: 23445197 Review.
Cited by
-
Investigation of biocidal efficacy of commercial disinfectants used in public, private and workplaces during the pandemic event of SARS-CoV-2.Sci Rep. 2022 Mar 31;12(1):5468. doi: 10.1038/s41598-022-09575-1. Sci Rep. 2022. PMID: 35361869 Free PMC article.
-
Comparative efficacy of hospital disinfectants against nosocomial infection pathogens.Antimicrob Resist Infect Control. 2020 Jul 22;9(1):115. doi: 10.1186/s13756-020-00781-y. Antimicrob Resist Infect Control. 2020. PMID: 32698895 Free PMC article.
-
Evaluation of efficacy of Aloe Vera as a Disinfectant by Immersion and Spray methods on Irreversible Hydrocolloid Impression Material and its Effect on the Dimensional Stability of Resultant Gypsum Cast - An in Vitro Study.J Med Life. 2019 Oct-Dec;12(4):395-402. doi: 10.25122/jml-2019-0050. J Med Life. 2019. PMID: 32025258 Free PMC article.
-
Occupational adverse effects and protective factors in bronchoscopy.J Thorac Dis. 2019 Apr;11(4):1651-1661. doi: 10.21037/jtd.2019.03.73. J Thorac Dis. 2019. PMID: 31179110 Free PMC article. Review.
-
Respiratory Symptoms in Hospital Cleaning Staff Exposed to a Product Containing Hydrogen Peroxide, Peracetic Acid, and Acetic Acid.Ann Work Expo Health. 2017 Dec 15;62(1):28-40. doi: 10.1093/annweh/wxx087. Ann Work Expo Health. 2017. PMID: 29077798 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources