Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
, 5 (1), 18

Reliability and Validity of the AGREE Instrument Used by Physical Therapists in Assessment of Clinical Practice Guidelines

Affiliations

Reliability and Validity of the AGREE Instrument Used by Physical Therapists in Assessment of Clinical Practice Guidelines

Joy C MacDermid et al. BMC Health Serv Res.

Abstract

Background: The AGREE instrument has been validated for evaluating Clinical Practice Guidelines (CPG) pertaining to medical care. This study evaluated the reliability and validity of physical therapists using the AGREE to assess quality of CPGs relevant to physical therapy practice.

Methods: A total of 69 physical therapists participated and were classified as generalists, specialist or researchers. Pairs of appraisers within each category evaluated independently, a set of 6 CPG selected at random from a pool of 55 CPGs.

Results: Reliability between pairs of appraisers indicated low to high reliability depending on the domain and number of appraisers (0.17-0.81 for single appraiser; 0.30-0.96 when score averaged across a pair of appraisers). The highest reliability was achieved for Rigour of Development, which exceeded ICC> 0.79, if scores from pairs of appraisers were pooled. Adding more than 3 appraisers did not consistently improve reliability. Appraiser type did not determine reliability scores. End-users, including study participants and a separate sample of 102 physical therapy students, found the AGREE useful to guide critical appraisal. The construct validity of the AGREE was supported in that expected differences on Rigour of Development domains were observed between expert panels versus those with no/uncertain expertise (differences of 10-21% p = 0.09-0.001). Factor analysis with varimax rotation, produced a 4-factor solution that was similar, although not in exact agreement with the AGREE Domains. Validity was also supported by the correlation observed (Kendall-tao = 0.69) between Overall Assessment and the Rigour of Development domain.

Conclusion: These findings suggest that the AGREE instrument is reliable and valid when used by physiotherapists to assess the quality of CPG pertaining to physical therapy health services.

Similar articles

See all similar articles

Cited by 23 PubMed Central articles

See all "Cited by" articles

References

    1. Guideline development in Europe. An international comparison. Int J Technol Assess Health Care. 2000;16:1039–1049. doi: 10.1017/S0266462300103101. - DOI - PubMed
    1. Burgers JS, Cluzeau FA, Hanna SE, Hunt C, Grol R. Characteristics of high-quality guidelines: evaluation of 86 clinical guidelines developed in ten European countries and Canada. Int J Technol Assess Health Care. 2003;19:148–157. doi: 10.1017/S026646230300014X. - DOI - PubMed
    1. Burgers JS, Grol R, Klazinga NS, Makela M, Zaat J. Towards evidence-based clinical practice: an international survey of 18 clinical guideline programs. Int J Qual Health Care. 2003;15:31–45. doi: 10.1093/intqhc/15.1.31. - DOI - PubMed
    1. Burgers JS, Fervers B, Haugh M, Brouwers M, Browman G, Philip T, Cluzeau FA. International assessment of the quality of clinical practice guidelines in oncology using the Appraisal of Guidelines and Research and Evaluation Instrument. J Clin Oncol. 2004;22:2000–2007. doi: 10.1200/JCO.2004.06.157. - DOI - PubMed
    1. Grimshaw JM, Hutchinson A. Clinical practice guidelines--do they enhance value for money in health care? Br Med Bull. 1995;51:927–940. - PubMed

Publication types

LinkOut - more resources

Feedback