A controlled trial of smart infusion pumps to improve medication safety in critically ill patients
- PMID: 15753744
- DOI: 10.1097/01.ccm.0000155912.73313.cd
A controlled trial of smart infusion pumps to improve medication safety in critically ill patients
Abstract
Objective: Intravenous medications are vital during inpatient management. Errors associated with the administration of medications through intravenous infusion pumps to critically ill patients can result in adverse drug events. We sought to assess the impact of smart pumps with integrated decision support software on the incidence and nature of medication errors and adverse drug events.
Design: We performed a prospective, randomized time-series trial and compared the serious medication error rate between intervention (decision support on) and control (decision support off) periods. Serious medication errors included both near-misses and preventable adverse drug events. Pump software produced log reports to help identify potential events. Events were presented to physicians for rating of event type, preventability, and severity.
Setting: Cardiac surgical intensive care and step-down units between February and December 2002.
Patients: Pump data were available for 744 cardiac surgery admissions.
Interventions: Decision support during medication administration provided feedback including alerts, reminders, and unit-specific drug rate limits.
Measurements and main results: We found a total of 180 serious medication errors, including 14 and 11 preventable adverse drug events and 73 and 82 nonintercepted potential adverse drug events in the control and intervention periods, respectively. The serious medication error rates in the control and intervention periods were 2.03 and 2.41 per 100 patient-pump-days, respectively (p = .124). We also found numerous opportunities for safety improvement. Violations of infusion practice during the intervention periods included 571 (25%) bypasses of the drug library. Medications were also frequently administered without documentation of physician orders in both periods (n = 823; 7.7%).
Conclusion: Intravenous medication errors and adverse drug events were frequent and could be detected using smart pumps. We found no measurable impact on the serious medication error rate, likely in part due to poor compliance. Although smart pumps have great promise, technological and nursing behavioral factors must be addressed if these pumps are to achieve their potential for improving medication safety.
Comment in
-
"Smart" pumps: A cautionary tale of human factors engineering.Crit Care Med. 2005 Mar;33(3):679-80. doi: 10.1097/01.ccm.0000155779.07020.9e. Crit Care Med. 2005. PMID: 15753769 No abstract available.
Similar articles
-
Programmable infusion pumps in ICUs: an analysis of corresponding adverse drug events.J Gen Intern Med. 2008 Jan;23 Suppl 1(Suppl 1):41-5. doi: 10.1007/s11606-007-0414-y. J Gen Intern Med. 2008. PMID: 18095043 Free PMC article.
-
Analysis of event logs from syringe pumps: a retrospective pilot study to assess possible effects of syringe pumps on safety in a university hospital critical care unit in Germany.Drug Saf. 2012 Jul 1;35(7):563-74. doi: 10.2165/11597350-000000000-00000. Drug Saf. 2012. PMID: 22671864
-
Intelligent intravenous infusion pumps to improve medication administration safety.AMIA Annu Symp Proc. 2003;2003:992. AMIA Annu Symp Proc. 2003. PMID: 14728495 Free PMC article. Clinical Trial.
-
Benefits and risks of using smart pumps to reduce medication error rates: a systematic review.Drug Saf. 2014 Dec;37(12):1011-20. doi: 10.1007/s40264-014-0232-1. Drug Saf. 2014. PMID: 25294653 Review.
-
Intravenous Smart Pumps: Usability Issues, Intravenous Medication Administration Error, and Patient Safety.Crit Care Nurs Clin North Am. 2018 Jun;30(2):215-224. doi: 10.1016/j.cnc.2018.02.004. Epub 2018 Apr 7. Crit Care Nurs Clin North Am. 2018. PMID: 29724440 Review.
Cited by
-
Effects of implementation strategies on nursing practice and patient outcomes: a comprehensive systematic review and meta-analysis.Implement Sci. 2024 Sep 30;19(1):68. doi: 10.1186/s13012-024-01398-0. Implement Sci. 2024. PMID: 39350295 Free PMC article.
-
The Impact of Smart Pump Technology in the Healthcare System: A Scope Review.Cureus. 2023 Mar 10;15(3):e36007. doi: 10.7759/cureus.36007. eCollection 2023 Mar. Cureus. 2023. PMID: 37051011 Free PMC article. Review.
-
The impact of drug error reduction software on preventing harmful adverse drug events in England: a retrospective database study.BMJ Open Qual. 2022 Jul;11(3):e001708. doi: 10.1136/bmjoq-2021-001708. BMJ Open Qual. 2022. PMID: 35820711 Free PMC article.
-
Detecting Unusual Intravenous Infusion Alerting Patterns with Machine Learning Algorithms.Biomed Instrum Technol. 2022 Apr 1;56(2):58-70. doi: 10.2345/0899-8205-56.2.58. Biomed Instrum Technol. 2022. PMID: 35749264 Free PMC article.
-
Artificial Intelligence for Identifying the Prevention of Medication Incidents Causing Serious or Moderate Harm: An Analysis Using Incident Reporters' Views.Int J Environ Res Public Health. 2021 Aug 31;18(17):9206. doi: 10.3390/ijerph18179206. Int J Environ Res Public Health. 2021. PMID: 34501795 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical