Automated acquisition of cryo-electron micrographs for single particle reconstruction on an FEI Tecnai electron microscope
- PMID: 15797731
- DOI: 10.1016/j.jsb.2005.01.002
Automated acquisition of cryo-electron micrographs for single particle reconstruction on an FEI Tecnai electron microscope
Abstract
AutoEM is a software package developed by Zhang et al. [J. Struct. Biol. 1356, 251] for semi-automated acquisition of cryo-electron micrographs from Tecnai series electron microscopes and is used frequently at the lowest level of automation. We report here on the new progress that we have made based on their preliminary work. A fourth low-dose state is created where the system can pre-select all the good holes in a grid square from a single CCD image taken at low magnification, making the system operative at much higher levels of automation. An additional control interface enables the operator to monitor the status of the program and the quality of the data, interact with the program, and direct the execution process according to intermediate results. When data acquisition is in progress, all useful information is automatically saved in certain text files which are easily accessible by a database. More detailed improvements and general advantages are illustrated and discussed. We have started to use the program to perform routine data collection. A number of applications show that the performance of the program is satisfactory and the quality of the micrographs and their power spectra acquired by the program is comparable to those manually collected under the same conditions.
Similar articles
-
Automated data collection with a Tecnai 12 electron microscope: applications for molecular imaging by cryomicroscopy.J Struct Biol. 2001 Sep;135(3):251-61. doi: 10.1006/jsbi.2001.4404. J Struct Biol. 2001. PMID: 11722165
-
Automated image acquisition for single-particle reconstruction using p97 as the biological sample.J Struct Biol. 2001 Feb-Mar;133(2-3):102-7. doi: 10.1006/jsbi.2001.4367. J Struct Biol. 2001. PMID: 11472082
-
Leginon: an automated system for acquisition of images from vitreous ice specimens.J Struct Biol. 2000 Oct;132(1):33-45. doi: 10.1006/jsbi.2000.4314. J Struct Biol. 2000. PMID: 11121305
-
Automated data collection in single particle electron microscopy.Microscopy (Oxf). 2016 Feb;65(1):43-56. doi: 10.1093/jmicro/dfv369. Epub 2015 Dec 15. Microscopy (Oxf). 2016. PMID: 26671944 Free PMC article. Review.
-
Introduction to 3D reconstruction of macromolecules using single particle electron microscopy.Acta Pharmacol Sin. 2005 Oct;26(10):1153-64. doi: 10.1111/j.1745-7254.2005.00203.x. Acta Pharmacol Sin. 2005. PMID: 16174429 Review.
Cited by
-
Dissection of the structure-function relationship of Nav channels.Proc Natl Acad Sci U S A. 2024 Feb 27;121(9):e2322899121. doi: 10.1073/pnas.2322899121. Epub 2024 Feb 21. Proc Natl Acad Sci U S A. 2024. PMID: 38381792 Free PMC article.
-
Cryo-EM structures of Candida albicans Cdr1 reveal azole-substrate recognition and inhibitor blocking mechanisms.Nat Commun. 2024 Sep 6;15(1):7722. doi: 10.1038/s41467-024-52107-w. Nat Commun. 2024. PMID: 39242571 Free PMC article.
-
Structural insights into the gating mechanism of human SLC26A9 mediated by its C-terminal sequence.Cell Discov. 2020 Aug 10;6:55. doi: 10.1038/s41421-020-00193-7. eCollection 2020. Cell Discov. 2020. PMID: 32818062 Free PMC article.
-
Graphene sandwich-based biological specimen preparation for cryo-EM analysis.Proc Natl Acad Sci U S A. 2024 Jan 30;121(5):e2309384121. doi: 10.1073/pnas.2309384121. Epub 2024 Jan 22. Proc Natl Acad Sci U S A. 2024. PMID: 38252835 Free PMC article.
-
A potent human monoclonal antibody with pan-neutralizing activities directly dislocates S trimer of SARS-CoV-2 through binding both up and down forms of RBD.Signal Transduct Target Ther. 2022 Apr 5;7(1):114. doi: 10.1038/s41392-022-00954-8. Signal Transduct Target Ther. 2022. PMID: 35383141 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
