Detection of acute infections during HIV testing in North Carolina
- PMID: 15872202
- DOI: 10.1056/NEJMoa042291
Detection of acute infections during HIV testing in North Carolina
Abstract
Background: North Carolina has added nucleic acid amplification testing for the human immunodeficiency virus (HIV) to standard HIV antibody tests to detect persons with acute HIV infection who are viremic but antibody-negative.
Methods: To determine the effect of nucleic acid amplification testing on the yield and accuracy of HIV detection in public health practice, we conducted a 12-month observational study of methods for state-funded HIV testing. We compared the diagnostic performance of standard HIV antibody tests (i.e., enzyme immunoassay and Western blot analysis) with an algorithm whereby serum samples that yielded negative results on standard antibody tests were tested again with the use of nucleic acid amplification. A surveillance algorithm with repeated sensitive-less-sensitive enzyme immunoassay tests was also evaluated. HIV infection was defined as a confirmed positive result on a nucleic acid amplification test or as HIV antibody seroconversion.
Results: Between November 1, 2002, and October 31, 2003, 109,250 persons at risk for HIV infection who had consented to HIV testing presented at state-funded sites. There were 606 HIV-positive results. Established infection, as identified by standard enzyme immunoassay or Western blot analysis, appeared in 583 participants; of these, 107 were identified, with the use of sensitive-less-sensitive enzyme immunoassay tests, as recent infections. A total of 23 acutely infected persons were identified only with the use of the nucleic acid amplification algorithm. With all detectable infections taken into account, the sensitivity of standard antibody testing was 0.962 (95 percent confidence interval, 0.944 to 0.976). There were two false positive results on nucleic acid amplification tests. The specificity and positive predictive value of the algorithm that included nucleic acid amplification testing were greater than 0.999 (95 percent confidence interval, 0.999 to >0.999) and 0.997 (95 percent confidence interval, 0.988 to >0.999), respectively. Of the 23 acute HIV infections, 16 were detected at sexually transmitted disease clinics. Emergency measures for HIV prevention protected 48 sex partners and one fetus from high-risk exposure to HIV.
Conclusions: The addition of nucleic acid amplification testing to an HIV testing algorithm significantly increases the identification of cases of infection without impairing the performance of diagnostic testing. The detection of highly contagious, acutely infected persons creates new opportunities for HIV surveillance and prevention.
Copyright 2005 Massachusetts Medical Society.
Comment in
-
Detection of acute HIV infections.N Engl J Med. 2005 Aug 11;353(6):631-3; author reply 631-3. doi: 10.1056/NEJM200508113530620. N Engl J Med. 2005. PMID: 16093476 No abstract available.
-
Detection of acute HIV infections.N Engl J Med. 2005 Aug 11;353(6):631-3; author reply 631-3. N Engl J Med. 2005. PMID: 16094766 No abstract available.
Similar articles
-
Performance of the new HIV-1/2 diagnostic algorithm in Florida's public health testing population: a review of the first five months of utilization.J Clin Virol. 2013 Dec;58 Suppl 1:e29-33. doi: 10.1016/j.jcv.2013.08.016. Epub 2013 Aug 27. J Clin Virol. 2013. PMID: 24342476
-
Screening for acute human immunodeficiency virus infection in Baltimore public testing sites.Sex Transm Dis. 2011 May;38(5):374-7. doi: 10.1097/OLQ.0b013e31820279bd. Sex Transm Dis. 2011. PMID: 21183865
-
Evaluation of an alternative HIV diagnostic algorithm using specimens from seroconversion panels and persons with established HIV infections.J Clin Virol. 2011 Dec;52 Suppl 1:S17-22. doi: 10.1016/j.jcv.2011.09.011. Epub 2011 Oct 5. J Clin Virol. 2011. PMID: 21981983
-
Measurement of HIV-1 p24 antigen by signal-amplification-boosted ELISA of heat-denatured plasma is a simple and inexpensive alternative to tests for viral RNA.AIDS Rev. 2002 Apr-Jun;4(2):83-92. AIDS Rev. 2002. PMID: 12152521 Review.
-
Human immunodeficiency virus: Diagnostic approach.Semin Diagn Pathol. 2017 Jul;34(4):318-324. doi: 10.1053/j.semdp.2017.04.008. Epub 2017 Apr 8. Semin Diagn Pathol. 2017. PMID: 28502523 Review.
Cited by
-
Development and evaluation of a high-sensitivity RT-PCR lateral flow assay for early detection of HIV-1 infection.Heliyon. 2024 Jun 12;10(12):e32784. doi: 10.1016/j.heliyon.2024.e32784. eCollection 2024 Jun 30. Heliyon. 2024. PMID: 38975074 Free PMC article.
-
Real-world performance of HIV low viral load values in diagnosing acute HIV infection in a tertiary care hospital in Beijing, China.BMC Infect Dis. 2024 Jun 15;24(1):587. doi: 10.1186/s12879-024-09486-8. BMC Infect Dis. 2024. PMID: 38879487 Free PMC article.
-
HIV testing: the cornerstone of HIV prevention efforts in the USA.Future Virol. 2011 Nov;6(11):10.2217/fvl.11.114. doi: 10.2217/fvl.11.114. Future Virol. 2011. PMID: 37965646 Free PMC article.
-
Characterizing Network-Based HIV Testing Interventions to Guide HIV Testing and Contact Tracing at STI Clinics in Lilongwe, Malawi.J Acquir Immune Defic Syndr. 2023 Oct 1;94(2):151-159. doi: 10.1097/QAI.0000000000003240. J Acquir Immune Defic Syndr. 2023. PMID: 37345996 Free PMC article. Clinical Trial.
-
Estimating the prevalence of two or more diseases using outcomes from multiplex group testing.Biom J. 2023 Oct;65(7):e2200270. doi: 10.1002/bimj.202200270. Epub 2023 May 16. Biom J. 2023. PMID: 37192524 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical